Configurations of 1 OTDR
and 36 ports
Configuration with one
internal optical switch and
one OSX8000
Configuration with one
internal optical switch and
more than one OSX8000
The OSX8000 replaces the OTAU plug-in. In this case, a blank plate
covers the place of the unnecessary module inside the OTU-8000.
1 Connect the OTDR plug-in to Common (on the OSX8000) with the
supplied jumper.
2 Connect all fibers to be tested from the ODF to OSX8000 ports.
OTDR
Fig. 30
Configuration 1 x 36
1 Connect C1 from the OSX8000 to port n of the internal optical
switch.
2 Connect all fibers to be tested from the ODF to OSX8000 ports.
Optical switch
1
Fig. 31
Configuration one OTAU and one OSX8000 («n» is the
max number of ports of the internal switch)
1 Connect C1 from the first OSX8000 to port 1 of the internal optical
switch.
2 Connect C1 from the last OSX8000 to port n of the internal optical
switch.
3 Connect the OTU-8000 to the first OSX8000, the first OSX8000 to
the second one, the second one to the third one etc., using
command cables.
4 Connect all fibers to be tested from the ODF to OSX8000 ports.
User Manual
7OTU80050/01
Chapter 3 Installation of the OTU-8000
OSX8000
Optical switch module
Common
Ports 1...36
OSX8000
C
Optical switch module
Ports
1...36
C1
1
36
Optical Switch
C
OTDR
module
n
C1
OSX8000 additional optical switch
ODF
29