Novoferm NovoPorta Premio T30-1 Instructions De Montage page 29

Table des Matières

Publicité

Maintenance and safety checks
The maintenance intervals will depend on intensity of use, but should take place a minimum of once a year. The maintenance instructions
set out below represent the minimum scope of the maintenance tasks to be carried out.
Component
Hinges
Pressure ball bearings
Handle fittings
Seals
Sills
Electrical door openers
Silicon seams
Surfaces
Locks
Usage information for NovoPorta Premio
1.
2.
No drill holes should be inserted
The handle pin should not be
in the lock area of any door leaf
forced through the spindle hub
where a lock has been installed.
of the lock.
6.
7.
Only press handle in normal
Lock the lock using only the
operating direction. A maxi-
key belonging to that lock
mum of 150 N may be exerted
(do not use unsuitable objects
in operating direction.
for this purpose).
11.
12.
No lock with lock cylinder with a
The emergency handle should only
thumbturn or rotary knob should
be operated in case of emergency
be fitted to emergency doors
(and not in normal operation).
Please keep these assembly, operating and maintenance instructions as long as you use the product!
Version
Hinges and locking parts should be checked regularly for correct positioning and wear
and tear. Fixation screws should be tightened up and parts replaced wherever necessary.
Door hinges are not maintenance-free: it is required to lubricate their bearings (except
3D hinges).
Where you detect damage (broken rings, defective coverings, broken or lost balls) replace
the bearing with a new one.
Check correct functioning: Handle must rest in horizontal position due to the spring force
of the lock. Check fixation.
Seals are sitting correctly, and checks should be made for damage and incomplete parts,
and such parts should be replaced where necessary. Only original seals approved by the
manufacturer should be used.
Sills should be checked for damage and correct positioning and should be replaced or
adjusted in position where appropriate. In addition, sealing should be checked for
completeness and should be renewed where appropriate.
Electrical door openers should be lubricated regularly.
Silicon seams should be checked for damage and incompleteness, and should be renewed
where necessary. Only silicone products that are chemically compatible with contiguous
parts should be used.
Surfaces should be checked annually for damage and completeness and repaired or re-
newed as necessary. If some unusual incident (e.g. an impact, or heavy hail, etc.) should
occur, then immediately after the incident a check should be made and remedial measures
taken in order to prevent downstream damage.
The free movement of latches and bolts should be checked. In cases where latches are
jammed, graphite oil can be sprayed into the lock chamber. In addition, latch bevels should
be lubricated in order to reduce sliding friction. Below you will find a number of notes from
the manufacturer of the lock on how to treat the lock.
(source: www.g-u.com)
3.
The door leaf should not be held
or carried by the door handle.
8.
The bolt should not be pre-
locked when the door is open.
13.
Double-leaf doors should not
be forced open by putting
pressure on the inactive leaf.
4.
5.
Space between strike plate and
lock mechanism: 2-5 mm, for
Neither bolt nor latch should
GU-Secury Automatic: 3-5 mm
be painted or varnished.
9.
10.
The handle and key should not
No key should be left inserted
be operated simultaneously.
in locks on emergency doors.
14.
15.
The lock must be replaced
immediately upon detecting
Lubricate locks at least once a
any sign of them being forced
year with non-resinous oil.
GB
29

Publicité

Table des Matières
loading

Table des Matières