6.2

Dismounting

Dismount the function module only if it is absolutely necessary (e.g. when the controller is replaced).
The pin strip which is used to connect the function module is part of the contact system of the
controller. It has not been designed for repeated connection and disconnection of the function
module.
Danger!
The pins of the FIF interface carry dangerous voltage!
Dismount the function module only when the controller is disconnected from the mains.
After disconnection from the mains wait for at least 3 minutes before you start working on the
module.
l
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Function modules (optional)
1. Disconnect the controller from the mains and wait for at least 3
minutes!
2. Remove the function module
8200vec279
EDK82EV903 DE/EN/FR 2.2
Dismounting
or
from the interface.