Code
Possible settings
No.
Name
Lenze
C0034*
Setpoint selection
range
Application I/O
(A)
uSEr
1 X3/1U, X3/1I
2 X3/2U, X3/2I
C0037
JOG1
C0038
JOG2
C0039
JOG3
C0087
Rated motor speed
C0088
Rated motor current
C0089
Rated motor
frequency
C0090
Rated motor voltage
C0091
Motor cos ϕ
C0119
Configuration of
motor temperature
monitoring (PTC
input) / earth fault
detection
C0140*
Additive frequency
setpoint
(NSET1-NADD)
C0148*
Motor parameter
identification
L
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Selection
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10 V
1
Bipolar voltage -10 V ... +10 V
2
Current 0 ... 20 mA
3
Current 4 ... 20 mA
4
Current 4 ... 20 mA open-circuit monitored
20.00
-650.00
30.00
-650.00
40.00
-650.00
300
0.0
50
10
50
0.40
0
0
PTC input not active
1
PTC input active,
TRIP set
2
PTC input active,
Warning set
3
PTC input not active
4
PTC input active,
TRIP set
5
PTC input active,
Warning set
0.00
-650.00
0
0
Ready
1
Start identification
V/f-rated frequency (C0015), slip compensation
(C0021) and motor stator inductivity (C0092) are
calculated and saved.
The motor stator resistance (C0084) = total
resistance of motor cable and motor is measured
and saved
EDK82EV903 DE/EN/FR 2.2
Commissioning
650.00 JOG = fixed setpoint
{0.02 Hz}
{0.02 Hz}
650.00
{0.02 Hz}
650.00
{1 rpm}
16000
{0.1 A}
650.0
{1 Hz}
960
{1 V}
500
{0.1}
1.0
Earth fault detection active
Earth fault detection
inactive
{0.02 Hz}
650.00
Code table
IMPORTANT
Observe the jumper setting of the function
module!
Minimum output frequency (C0010) not effective
Changing the direction of rotation is only
possible with a digital signal.
Changing the direction of rotation is only
possible with a digital signal.
TRIP Sd5 if I < 4 mA
Additional fixed setpoints
C0440
Depending on the controller
Depending on the controller
0.0 ... 2.0 x rated output current of the
controller
230 V with 230 V controllers,
400 V with 400 V controllers
Depending on the controller
Signal output configuration under C0415
If several parameter sets are used, the
monitoring must be separately adjusted for
each parameter set.
Deactivate the earth fault detection, if it has
been activated unintentionally.
If the earth fault detection is active, the
motor starts after controller enable with a
delay of approx.40 ms.
Selection via function
of the keypad or
the parameter channel
Is added to main setpoint
Value is stored when switching the mains or
removing the keypad
Only when the motor is cold!
1. Inhibit controller, wait until drive is at
standstill
2. Enter the correct motor data under C0087,
C0088, C0089, C0090, C0091 (see motor
nameplate).
3. Set C0148 = 1 by
4. Enable controller
The identification
– starts,
goes off
– the motor makes a high-pitched tone, but
does not rotate!
– takes approx. 30 s
– is completed when
is on again
5. Inhibit controller
105