Lenze Global Drive 8200 vector Instructions De Montage page 104

Masquer les pouces Voir aussi pour Global Drive 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Code
Possible settings
No.
Name
Lenze
C0007
Fixed configuration of
digital inputs
uSEr
C0007
uSEr
(cont.)
C0007
uSEr
(cont.)
C0007
uSEr
(cont.)
L
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Selection
0
E4
0
CW/CCW
1
CW/CCW
2
CW/CCW
3
CW/CCW
4
CW/CCW
5
CW/CCW
6
CW/CCW
7
CW/CCW
8
CW/CCW
9
CW/CCW
10
CW/CCW
TRIP set
E4
11
CW/CCW
12
CW/CCW
13
CW/CCW
14
CCW/QSP
CW/QSP
15
CCW/QSP
CW/QSP
16
CCW/QSP
CW/QSP
17
CCW/QSP
CW/QSP
18
CCW/QSP
CW/QSP
19
CCW/QSP
CW/QSP
E4
20
CCW/QSP
CW/QSP
21
CCW/QSP
CW/QSP
22
CCW/QSP
CW/QSP
23
H/Re
CW/CCW
24
H/Re
25
H/Re
26
H/Re
JOG1/3
27
H/Re
TRIP set
28
JOG2/3
JOG1/3
29
JOG2/3
30
JOG2/3
E4
31
DCB
32
TRIP set
33
QSP
34
CW/QSP
CCW/QSP
35
JOG2/3
JOG1/3
36
DCB
37
JOG1/3
38
JOG1/3
39
JOG2/3
JOG1/3
40
JOG1/3
EDK82EV903 DE/EN/FR 2.2
Commissioning
E3
E2
E1
DCB
JOG2/3
JOG1/3
PAR
JOG2/3
JOG1/3
QSP
JOG2/3
JOG1/3
PAR
DCB
JOG1/3
QSP
PAR
JOG1/3
DCB
TRIP set
JOG1/3
PAR
TRIP set
JOG1/3
PAR
DCB
TRIP set
QSP
PAR
TRIP set
QSP
TRIP set
JOG1/3
UP
DOWN
E3
E2
E1
DCB
UP
DOWN
PAR
UP
DOWN
QSP
UP
DOWN
DCB
JOG1/3
PAR
JOG1/3
JOG2/3
JOG1/3
PAR
DCB
PAR
TRIP set
DCB
TRIP set
E3
E2
E1
TRIP set
JOG1/3
UP
DOWN
UP
JOG1/3
UP
DOWN
PAR
UP
DOWN
DCB
UP
DOWN
UP
DOWN
UP
DOWN
DFIN1-ON
PCTRL1-I-OFF
DCB
DFIN1-ON
PCTRL1-I-OFF
QSP
DFIN1-ON
PCTRL1-I-OFF
E3
E2
E1
QSP
DFIN1-ON
PCTRL1-I-OFF
QSP
DFIN1-ON
PCTRL1-I-OFF
PAR
DFIN1-ON
PCTRL1-I-OFF
DFIN1-ON
PCTRL1-I-OFF
PAR
DFIN1-ON
QSP
PAR
DFIN1-ON
QSP
PAR
DFIN1-ON
PAR
TRIP set
DFIN1-ON
TRIP set
DFIN1-ON
QSP
TRIP set
DFIN1-ON
Code table
IMPORTANT
Change under C0007 will be copied to the
corresponding subcode of C0410. Free
configuration under C0410 sets C0007 =
255!
CW/CCW = CW rotation/CCW rotation
DCB = DC injection brake
QSP = Quick stop
PAR = Parameter set changeover (PAR1
PAR2)
– PAR1 = LOW, PAR2 = HIGH
– The terminal must be assigned to the
function "PAR" in PAR1 and PAR2.
– Configurations with "PAR" are only
allowed if C0988 = 0
TRIP set = external fault
JOG1/3, JOG2/3 = Selection of fixed
setpoints
– Activate JOG1:
JOG1/3 = HIGH; JOG2/3 = LOW
– Activate JOG2:
JOG1/3 = LOW; JOG2/3 = HIGH
– Activate JOG3:
JOG1/3 = HIGH; JOG2/3 = HIGH
UP/DOWN = motor potentiometer functions
H/Re = Hand/remote changeover
PCTRL1-I-OFF = Switch off process
controller I component
DFIN1-ON = Digital frequency input 0 ... 10
kHz
PCTRL1-OFF = Switch off process controller
103

Publicité

Table des Matières
loading

Table des Matières