Commissioning
Code table
Code
Possible settings
No.
Name
Lenze
C0002*
Parameter set
transfer using the
keypad
uSEr
(cont.)
C0002*
Saving of own
settings
uSEr
(cont.)
C0002*
Loading/copying of
your own basic
settings
uSEr
(cont.)
C0003*
Non-volatile
parameter saving
102
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Selection
Keypad
PAR1 (+ FPAR1)
71
With function module Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B, DeviceNet/CANopen
11
With all other function modules
Keypad
PAR2 (+ FPAR1)
72
With function module Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B, DeviceNet/CANopen
12
With all other function modules
Keypad
PAR3 (+ FPAR1)
73
With function module Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B, DeviceNet/CANopen
13
With all other function modules
Keypad
PAR4 (+ FPAR1)
74
With function module Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B, DeviceNet/CANopen
14
With all other function modules
Controller
Keypad
80
With function module Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B, DeviceNet/CANopen
20
With all other function modules
Keypad
Function module
40
Only with function module INTERBUS, PROFIBUS-DP,
LECOM-B, DeviceNet/CANopen
Function module
50
Only with function module INTERBUS, PROFIBUS-DP,
LECOM-B, DeviceNet/CANopen
9
PAR1
Own settings
5
Own settings
PAR1
6
Own settings
PAR2
7
Own settings
PAR3
8
Own settings
PAR4
1
0
Parameter not saved in EEPROM
1
Parameter always saved in EEPROM
3
Own settings saved in EEPROM
EDK82EV903 DE/EN/FR 2.2
IMPORTANT
Overwrite selected parameter set and, if
necessary, FPAR1 with the corresponding
keypad data
All available parameter sets (PAR1 ... PAR4, and
FPAR1) are copied to the keypad
Overwrite the module-specific parameter set
FPAR1 only
Copy the module-specific parameter set FPAR1
Keypad
only
You can save your own basic settings for a
controller (e.g. machine delivery status):
1. Ensure that parameter set 1 is active
2. Controller inhibit
3. Set C0003 = 3, acknowledge with
4. Set C0002 = 9, acknowledge with
5. Set C0003 = 1, acknowledge with
6. Enable the controller.
Using this function, PAR1 can be copied to
parameter sets PAR2 ... PAR4
Restorage of own basic setting in the selected
parameter set
Data loss after mains disconnection
Subsequently save parameter set 1 as own
basic setting with C0002 = 9
save your own basic settings
Active after every mains connection
Cyclic parameter changes via bus module
are not allowed.