Electrical installation

Power connections E82EV753K4B / E82EV903K4B

5.4
Power connections E82EV753K4B / E82EV903K4B
5.4.1

Mains connection

Connection with mains choke
Connection with subassembled mains filter
Connection with built-on assembled mains filter
Fuses and cable cross-sections
Type
mains
E82EV753K4B 3/PE AC 320 V -0 % ... 550 V +0 %
45 Hz -0 % ... 65 Hz +0 %
E82EV903K4B
DC 450 V -0 % ... 775 V +0 %
1)
Use UL-approved cables, fuses and fuse holders only.
UL fuse: 500 ... 600 V, tripping characteristic "H", "K5" or "CC"
2)
All-current sensitive e.l.c.b.
Observe national and regional regulations (e. g. VDE 0113, EN 60204)
Please observe the following when using e.l.c.bs.:
E.l.c.bs must only be installed between mains supply and controller.
Earth leakage circuit breakers can be activated although not required by
– capacitive compensating currents of the cable shields during operation (especially with long,
shielded motor cables),
– simultaneous connection of several controllers to the mains supply,
– use of additional RFI filters.
82
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Connection brake chopper (  Operating Instructions for the brake chopper )
Connection mains filter temperature monitoring with PTC thermistor
Z1 Mains choke/mains filter
Installation to EN 60204-1
Fuse
L1, L2, L3, PE [mm
M160 A
70
M200 A
95
EDK82EV903 DE/EN/FR 2.2
1)
Installation to UL
2
]
Fuse
L1, L2, L3, PE [AWG]
175 A
2 / 0
200 A
3 / 0
8200vec290
2)
FI
≥300 mA