Safety information

1.1

General safety and application notes for Lenze controllers

(according to Low-Voltage Directive 73/23/EEC)
1. General
Lenze controllers (frequency inverters, servo inverters, DC controllers) can carry a voltage or parts of the controllers can rotate during operation. Surfaces can be hot.
If the required cover is removed, the controllers are used inappropriately or installed or operated incorrectly, severe damage to persons or material assets can occur.
For more information please see the documentation.
All operations concerning transport, installation, and commissioning as well as maintenance must be carried out by qualified, skilled personnel (IEC 364 and CENELEC HD
384 or DIN VDE 0100 and IEC report 664 or DIN VDE 0110 and national regulations for the prevention of accidents must be observed).
According to this basic safety information qualified, skilled personnel are persons who are familiar with the assembly, installation, commissioning, and operation of the
product and who have the qualifications necessary for their occupation.
2. Intended use
Drive controllers are components which are designed for the installation into electrical systems or machinery. They are not to be used as domestic appliances, but only
for industrial purposes according to EN 61000-3-2. The documentation contains information about the compliance of the limit values with EN 61000-3-2.
When installing controllers into machines, commissioning of the drive controllers (i.e. the starting of operation as directed) is prohibited until it is proven that the machine
corresponds to the regulations of the EC Directive 98/37/EG (Machinery Directive); EN 60204 (VDE 0113) must be observed.
Commissioning (i.e. starting of operation as directed) is only allowed when there is compliance with the EMC Directive (89/336/EEC).
The drive controllers meet the requirements of the Low-Voltage Directive 73/23/EEC. The harmonised standards EN 50178/DIN VDE 0160 apply to the controllers.
The technical data as well as the connection conditions can be obtained from the nameplate and the documentation. The instructions given must be strictly observed.
Warning: Controllers are products with restricted availability according to EN 61800-3. These products can cause interferences in residential premises. If controllers are
used in residential premises, corresponding measures are required.
3. Transport, storage
The notes on transport, storage and appropriate handling must be observed.
Climatic conditions according to EN 50178 apply.
4. Installation
The controllers must be installed and cooled according to the regulations given in the corresponding Instructions.
Ensure careful handling and avoid mechanical overload. Do not bend any components and do not change the insulation distances during transport and storage. Electronic
components and contacts must not be touched.
Controllers contain electrostatically sensitive components which can easily be damaged by inappropriate handling. Do not damage or destroy any electrical components
since this could mean hazards for your health!
5. Electrical connection
When working on live controllers, the valid national regulations for the prevention of accidents (e. g. VBG 4) must be observed.
The electrical installation must be carried out in compliance with the corresponding regulations (e.g. cable cross-sections, fuses, PE connection). Additional notes and
information can be obtained from the corresponding Instructions.
The Instructions contain notes concerning wiring according to EMC regulations (shielding, earthing, filters and cable routing). These notes must also be observed when
using CE-marked controllers. The compliance with limit values required by the EMC legislation is the responsibility of the manufacturer of the machine or system.
6. Operation
If necessary, systems including controllers must be equipped with additional monitoring and protection devices according to the applying safety regulations (e.g. regulation
for technical equipment, regulation for the prevention of accidents). The controller can be adapted to your application. Please observe the corresponding information given
in the Instructions.
After a controller has been disconnected from the voltage supply, all live components and power connections must not be touched immediately because capacitors can
still be charged. Please observe the corresponding stickers on the controller.
All protection covers and doors must be shut during operation.
Note for UL-approved systems with integrated controllers: UL warnings are notes which only apply to UL systems. The Instructions give UL-related information.
7. Safe standstill
The variant V004 of 9300 and 9300 vector, the variant Bx4x of 8200 vector controller and the axis controller ECSXA064 support the function "Safe standstill", protection
against unexpected start, according to the requirements of Annex I No. 1.2.7 of the EC Directive "Machinery" 98/37/EG, DIN EN 954-1 category 3 and DIN EN 1037. Please
observe the notes on the function "Safe standstill" given in the corresponding Instructions.
8. Maintenance and service
Please observe the Instructions given by the manufacturer.
Please observe the product-specific safety and application notes in these Instructions.
L