Mounting And Dismounting Function Modules - Lenze 8200 vector Instructions De Montage

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.1.1

Mounting and dismounting function modules

{
Danger!
Dangerous electrical voltage
Terminals can carry dangerous electrical voltage − also if the motor is stopped
or after the mains is switched off!
Possible consequences:
ƒ
Protective measures:
Before all operations on the controller
ƒ
ƒ
EDK82EV903 DE/EN/FR 5.1
Mounting and dismounting function modules
Death or severe injuries when touching live terminals.
Switch off the mains voltage and wait for at least 3 minutes.
Check whether terminals are isolated from supply, since
– the power terminals U, V, W, +UG, −UG, BR1, BR2, and the pins of the FIF
interfaces still carry dangerous voltage for at least 3 minutes after
power−off.
– the power terminals L1, L2, L3; U, V, W, +UG, −UG, BR1, BR2, and the pins of
the FIF interfaces carry dangerous voltage when the motor is stopped.
– the relay outputs K11, K12, K14 can carry dangerous voltage when the
drive controller is disconnected from the mains.
l
Extensions for automation
6
Modules
161

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E82ev153k4b2E82ev223k4b2E82ev303k4b2

Table des Matières