Lenze 8200 vector Instructions De Montage page 181

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Code
Possible settings
No.
Name
Lenze
C0034*
Range of
v
setpoint
selection
uSEr
Standard I/O
(X3/8)
C0034*
Range of
v
setpoint
selection
(A)
Application I/O
uSEr
1 X3/1U, X3/1I
2 X3/2U, X3/2I
C0037
JOG1
20.00 −650.00
C0038
JOG2
30.00 −650.00
C0039
JOG3
40.00 −650.00
C0050*
Output
frequency
uSEr
(MCTRL1−NOUT)
à
C0087
Rated motor
speed
à
C0088
Rated motor
current
C0089
Rated motor
frequency
à
C0090
Rated motor
voltage
à
Motor cos 
C0091
C0119
Configuration of
v
motor
temperature
monitoring (PTC
input) / earth
fault detection
EDK82EV903 DE/EN/FR 5.1
Important codes for quick commissioning
Selection
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10 V
Current 0 ... 20 mA
1
Current 4 ... 20 mA
2
Bipolar voltage −10 V ... +10 V
3
Current 4 ... 20 mA open−circuit monitored
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10 V
1
Bipolar voltage −10 V ... +10 V
2
Current 0 ... 20 mA
3
Current 4 ... 20 mA
4
Current 4 ... 20 mA open−circuit monitored
{0.02 Hz}
{0.02 Hz}
{0.02 Hz}
−650.00
{Hz}
300
{1 rpm}
0.0
0.1 (A)
50
10
{1 Hz}
50
{1 V}
0.40
{0.1}
0
0
PTC input inactive
1
PTC input active,
TRIP effected
2
PTC input active,
warning effected
3
PTC input inactive
4
PTC input active,
TRIP effected
5
PTC input active,
warning effected
l
Commissioning
IMPORTANT
Observe switch position of the
function module!
Reversal of rotation direction only
possible with a digital signal.
l
Minimum output frequency
(C0010) not effective
l
Individually adjust offset and gain
TRIP Sd5 if I < 4 mA
Reversal of rotation direction only
possible with a digital signal.
Observe jumper position of the
function module!
Minimum output frequency (C0010)
not effective
Reversal of rotation direction only
possible with a digital signal.
Reversal of rotation direction only
possible with a digital signal.
TRIP Sd5 at I < 4 mA
650.00 JOG = fixed setpoint
Additional fixed setpoints ðC0440
650.00
650.00
650.00 Read only: Output frequency without
slip compensation
à
16000
Device−dependent
à
650.0
Device−dependent
0.0 ... 2.0 x rated output current of the
controller
960
à
500
230 V for 230 V controllers,
400 V for 400 V controllers
à
1.0
Device−dependent
l
Earth fault detection
Configure signal output in C0415
active
l
If several parameter sets are used,
monitoring has to be set
separately for every parameter set.
l
Deactivate earth fault detection if
the earth fault detection is
Earth fault detection
actuated unintentionally.
inactive
l
If the earth fault detection is
activated, the motor starts with a
delay of approx. 40 ms after
controller enable has been set.
7
181

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E82ev153k4b2E82ev223k4b2E82ev303k4b2

Table des Matières