Lenze 8200 vector Instructions De Montage page 187

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1)
Keypad
PC
Fault
95
Fan failure
FAn1
a
(only 8200 motec
3 ... 7.5 kW)
FAn1
TRIP or warning
configurable in C0608
105
Internal fault
H05
a
140
Faulty parameter
id1
a
identification
32
Motor phase error
LP1
a
(display when C0597 =
1)
182
Motor phase error
LP1
(Display when C0597 =
2)
DC−bus undervoltage
LU
c
11
Short circuit
OC1
a
12
Earth fault
OC2
a
13
Controller overload
OC3
a
during acceleration or
short circuit
14
Controller overload
OC4
a
during deceleration
15
Controller overload
OC5
a
during steady−state
operation
16
Motor overload
OC6
a
2
(I
x t overload)
50
Heatsink temperature >
OH
a
+85 °C
Heatsink temperature >
OH
e
+80 °C
Heatsink temperature >
OH
e
+80 °C
53
PTC monitoring (TRIP)
OH3
a
(display when
C0119 = 1 or 4)
EDK82EV903 DE/EN/FR 5.1
Troubleshooting and fault elimination
Cause
Fan is defective
Fan is not connected
Motor is not connected
l
Failure of one/several motor phases
l
Motor current is too low
Mains voltage is too low
Voltage in DC−bus connection is too
low
400 V controller is connected to 240 V
mains
Short circuit
Capacitive charging current of the
motor cable is too high
A motor phase has earth contact
Capacitive charging current of the
motor cable is too high
Set acceleration time is too short
(C0012)
Defective motor cable
Interturn fault in the motor
Set deceleration time is too short
(C0013)
Frequent and too long overload periods Check drive dimensioning
Motor is thermally overloaded by e.g.
l
impermissible continuous current
l
frequent or too long acceleration
processes
Ambient temperature is too high
Heatsink is very dirty
Impermissible high currents or
frequent and too long acceleration
processes
Motor too hot due to impermissible
high currents or frequent and too long
acceleration processes
No PTC connected
l
Fault elimination
Fault messages
Remedy
Replace fan
Connect fan
Check wiring
Contact Lenze
Connect motor
l
Check motor supply cables
l
Check V
boost,
min
l
Connect motor with a corresponding
power or adapt motor with C0599
Check mains voltage
Check power supply module
Connect controller to correct mains voltage
l
Search for cause of short circuit; check
motor cable
l
Check brake resistor and cable to brake
resistor
Use shorter/low−capacitance motor cable
Check motor; check motor cable
Use shorter/low−capacitance motor cable
Deactivate earth−fault detection for test
purposes
l
Increase acceleration time
l
Check drive dimensioning
Check wiring
Check motor
l
Increase deceleration time
l
Check dimensioning of the external brake
resistor
l
Check drive dimensioning
l
Check setting of C0120
Allow controller to cool and provide for
better ventilation
Clean heatsink
l
Check drive dimensioning
l
Check load, replace rough−running,
defective bearings, if necessary
Check drive dimensioning
Connect PTC or switch off monitoring