Safety instructions
General safety information
Mechanical installation
Install the product according to the regulations of the corresponding
ƒ
documentation. In particular observe the section "Operating conditions" in the
chapter "Technical data".
Provide for a careful handling and avoid mechanical overload. During handling
ƒ
neither bend components, nor change the insulation distances.
The product contains electrostatic sensitive devices which can easily be damaged by
ƒ
short circuit or static discharge (ESD). Thus, electronic components and contacts
must not be touched unless ESD measures are taken beforehand.
Electrical installation
Carry out the electrical installation according to the relevant regulations (e. g. cable
ƒ
cross−sections, fusing, connection to the PE conductor). Additional notes are
included in the documentation.
When working on live products, observe the applicable national regulations for the
ƒ
prevention of accidents (e.g. BGV 3).
The documentation contains information about EMC−compliant installation
ƒ
(shielding, earthing, arrangement of filters and laying cables). The system or
machine manufacturer is responsible for compliance with the limit values required
by EMC legislation.
Warning: The controllers are products which can be used in category C2 drive systems
as per EN 61800−3. These products may cause radio interference in residential areas. If
this happens, the operator may need to take appropriate action.
For compliance with the limit values for radio interference emission at the site of
ƒ
installation, the components − if specified in the technical data − have to be mounted
in housings (e. g. control cabinets). The housings have to enable an EMC−compliant
installation. In particular observe that for example control cabinet doors preferably
have a circumferential metallic connection to the housing. Reduce openings or
cutouts through the housing to a minimum.
Only plug in or remove pluggable terminals in the deenergised state!
ƒ
Commissioning
If required, you have to equip the system with additional monitoring and protective
ƒ
devices in accordance with the respective valid safety regulations (e. g. law on
technical equipment, regulations for the prevention of accidents).
Before commissioning remove transport locking devices and keep them for later
ƒ
transports.
Safety functions
Without a higher−level safety system, the described product must neither be used
ƒ
for the protection of machines nor persons.
Certain controller versions support safety functions (e.g. "Safe torque off", formerly
ƒ
"Safe standstill").
The notes on the safety functions provided in the documentation of the versions must
be observed.