6
Extensions for automation
Modules
Mounting and dismounting function modules
Mounting
The following worksteps apply to the interfaces FIF I (at the top) and FIF II (at the bottom).
1. Disconnect the drive controller from mains and wait at least 3 minutes!
2. Carefully press the clip 0 upwards and remove the function module 1.
3. Remove the FIF cover 2.
4. Plug the function module 3 onto the terminals of the interface.
– Make sure that the pins of the FIF interface are plugged correctly in the sockets of
the function module and are not bent.
5. Push the blanking cover 3 until the clip 0 locks into place.
– Without the FIF cover 2, the controller is inhibited.
– If no function module is plugged on, the controller without FIF cover 2 and
blanking cover 1 must not be commissioned (dangerous electrical voltage at the
FIF interface).