Insert cable
Fig. 11: Insert cable
1
Strain relief
Procedure
Insert the included cable glands with the appropriate seals in the matching cable
n
insertion holes of the housing and fix it with the lock nuts.
n
Insert one cable through a cable gland and tighten the cable gland.
Make sure the cable is well sealed.
n
Close off unneeded cable glands using the supplied sealing plugs and tighten the
cable glands tightly.
n
Core cables: Strip the cable so that the sheath reaches to the top of the mounting tabs
of the mounting strip (1). Make sure the shields are properly isolated when assembling
cables. Assembly of coaxial cables:
Ä Chapter 7.2.3 'Assembly of coaxial cable for pH / ORP electrodes' on page 52
See
n
For strain relief, fix the cable with cable ties to a free strap of the strain relief (1).
Connect the cable according to the wiring diagram.
n
See:
Ä Chapter 7.5 'Terminal connection diagrams for base part' on page 56
Ä Chapter 7.6 'Terminal Connection Diagrams Measuring Modules / Measured Value
Inputs' on page 59
Ä Chapter 7.7 'Wiring diagrams option boards' on page 73
Open or improperly sealed cable glands make the IP67 protection of the
housing ineffective. Ensure that all cable glands are closed or screwed tight
with the correct installation torque.
See:
Ä Chapter 13.16 'Housing' on page 251.
2
Cable gland IP67
51
Electrical connection