2 . 2 Relay outs

2 . 2
2 . 2
2 . 2
2 . 2
Relay outs
Relay outs
Relay outs
Relay outs
C
3
OUT 1
NO
4
C
5
OUT 2
NO
6
Fig. 5 RELAY OUTPUTS WIRING
The contact rating the relay outputs is 3A/250V AC on resistive
load.
The number of operations is 1 x 10
at specified rating.
5
N O T E S :
N O T E S :
N O T E S :
N O T E S :
N O T E S :
1) To avoid electrical shock, connect power line at the end of the
wiring procedure.
2) For power connections, use AWG 16 or 14 wires rated for at
least 75 °C.
3) Use copper conductors only.
4) Don't run input wires together with power cables.
All relay contacts are protected by varistor against inductive load
with inductive component up to 0.5 A.
fks-MK1-1-A0.pmd
3
2.2.1
2.2.1 Voltage outputs for SSR drive
2.2.1
2.2.1
2.2.1
Voltage outputs for SSR drive
Voltage outputs for SSR drive
Voltage outputs for SSR drive
Voltage outputs for SSR drive
+
3
OUT 1
_
4
+
5
_
OUT 2
6
Fig. 6 SSR DRIVE OUTPUTS WIRING
They are time proportioning outputs.
Logic level 0: Vout < 0.5 V c.c.
Logic level 0
Logic level 0
Logic level 0
Logic level 0
Logic level 1
Logic level 1
Logic level 1
Logic level 1: - 14 Vc.c. + 20 % @ 20 mA
Logic level 1
- 24 Vc.c. + 20 % @ 1 mA
Maximum current = 20 mA.
N O T E
N O T E
N O T E
N O T E :
N O T E
These outputs are not isolated. The external solid state relay
must guarantee a double or reinforced isolation between
instrument output and power supply.
GB
3
09/05/2006, 15.05
+
_
SOLID STATE
RELAY
+
_
SOLID STATE
RELAY