ON
ON
1
OFF
OFF
2
3
4
Gas
Models
Only
5
Figure 14
All manuals and user guides at all-guides.com
MAN
8
AUTO
6
7
13
Operation
OPERATION
NOTE: Operation is restricted to qualified person-
nel.
1. Turn on the gas valve. (Gas models only.)
2. Close the oven door.
3. Turn the BLOWER Switch (1) on the front panel
to ON. Set the COOL DOWN Switch (8) to
AUTO.
The fan will start to turn and the temperature
control will go on.
4. Set THERMOSTAT (3) to the desired tempera-
ture.
The burner will ignite or the elements will come
on. The OVEN READY light (2) on the control
panel will illuminate.
For gas models if in starting, the burner does
not ignite within a few seconds, the RESET
alarm light (4) will go on. Press the RESET
switch (5) to restart the burner.
The LIGHT OFF OVEN READY light (2) will go
out when the oven has reached temperature.
NOTE: If the oven will not start after several at-
tempts contact a qualified installer.
For the HUMIDAIRE control option:
1. Momentarily press and release the STEAM
CYCLE START button (7). The STEAM indica-
tor (6) will light as water is injected into the
baking compartment.
Cool Down
1. Open oven door
2. Set the BLOWER Switch to ON.
3. Set COOL DOWN Switch (8) to MANUAL.
Shut Down
1. Turn the BLOWER Switch (1) to OFF.
2. Turn the THERMOSTAT (3) to OFF.
3. Shut off the gas valve. (Gas models only.)
Zephaire Controls