GAS HOSE RESTRAINT (gas models)
If the oven is mounted on casters, a commercial
flexible connector with a minimum of 1.9 cm inside
diameter must be used along with a quick connect
device.
1. Mount the supplied bracket to the leg bolt just
below the gas inlet.
2. Attach the clip on restraining cable to the
mounting bracket.
Restraint Cable
Bracket
Double stacked unit shown.
Figure 9
All manuals and user guides at all-guides.com
Back of Oven
7
Installation
VENTILATION (gas models)
A mechanically driven, canopy type exhaust hood
is required. The hood should completely cover the
oven with an overhang of at least 15 cm on all
sides not adjacent to a wall. The distance from the
floor to the lower edge of the hood should not ex-
ceed 2.1m.
WARNING:
Failure to properly vent the oven can be
hazardous to the health of the operator
and may result in operational problems,
unsatisfactory baking and possible dam-
age to the equipment.
Damage sustained as a direct result of im-
proper ventilation will not be covered by
the manufacturer's warranty.
Ovens ordered for hood venting are supplied with
a draft diverter. Install the draft diverter as follows:
1. Place the diverter over the flue connector with
the open area facing the front of the oven.
2. Secure with the sheet metal screws provided.
Draft Diverter
Full Size Oven Shown
Figure 10
Oven Assembly