To change a setting, place the highlight on the desired line using the Up/
Down arrow buttons and use the Left/Right arrow buttons to increase or
decrease the delay. To return to the MAIN menu, press the BACK button or
select "BACK" on the OSD. Press the SETUP button or select "EXIT" on the
OSD to exit setup and return to normal operation.

Miscellaneous Settings

System Setup

SYSTEM SETUP
LANGUAGE
IR REMOTE CODESET
DISPLAY
NETWORK WAKEUP
POWER OPTION
NETWORK CONFIGURATION
SOFTWARE INFORMATION
RESTORE FACTORY DEFAULT
BACK
This SYSTEM SETUP menu, reached from the MAIN menu, provides access
to several miscellaneous settings as follows:
LANGUAGE: Selects a language for the On Screen Display.
IR REMOTE CODESET: The RSP-1576MKII has two IR codesets and can be
changed in the event there is a conflict of IR codes with other Rotel products.
NOTE: After changing the IR REMOTE CODESET the remote must
also be changed to continue using the remote control. Push and hold
the TUNER button and 1 (or TUNER and 2 for codeset 2) at the same
time and hold for approximately 5 seconds until the backlights on the
remote control blink on then off then release both buttons. This sets the
remote control to use codeset 1 (or codeset 2 if TUNER and 2 are held).
DISPLAY: Sets the information shown on the main HDMI OSD and front VFD
display. Settings are "Off", "HDMI ONLY", "VFD ONLY" or "HDMI AND VFD".
NETWORK WAKEUP: Enable or Disable power on and power off via the
network connection. Enable this function for use with automation systems
using IP control.
NOTE: The Network Wakeup function is not available in all regions.
NOTE: When Network Wakeup is configured to enabled, the RSP-
1576MKII will consume additional power in standby mode.
POWER OPTION: Access to configuration of Off Timer, Max Power On
Volume, Power Mode and Signal Sense Input.
POWER OPTION
OFF TIMER
MAX POWER ON VOLUME
POWER MODE
SIGNAL SENSE INPUT
BACK
ENGLISH
CODESET 1
HDMI AND VFD
DISABLE
20 MINS
45
NORMAL
DISABLE
RSP-1576MKII Surround Sound Processor
OFF TIMER: Set the amount of time the units stays powered on when
there is no audio signal. The RSP-1576MKII will automatically go to
standby mode if audio is not detected for the specified timer period.
Default: 20 MINS.
Valid settings include: Disable, 20 MINS, 1 HOUR, 2 HOURS, 4 HOURS.
MAX POWER ON VOLUME: Specifies the maximum volume level to be
used each time the unit powered on. Valid settings include: 20 - 70.
Default: 45.
POWER MODE: Enables the rear panel USB power port and the Network
connection to remain powered at all times. The power consumption is
higher in Quick Power mode. To enable continuous power to the rear USB
power port and allow for IP control of Power-On select the Quick option.
Valid settings include: NORMAL, QUICK.
NOTE: When the POWER MODE is configured to Quick, the RSP-
1576MKII will consume additional power in standby mode.
NOTE: Some regions limit the amount of Standby Power Consumption
allowed and the POWER MODE will not be available. To control the
Rotel product in this case use the RS232 connection. For questions
on the availablity of the Power Mode please contact your authorized
Rotel dealer.
SIGNAL SENSE INPUT: Checks if a digital audio signal is present on the
configured Signal Sense Input. When this input is selected as the active
listening source, the RSP-1576MKII monitors the digital data stream to
determine if there is audio. If there is no audio detected for 10 minutes,
the RSP-1576MKII will enter Signal Sense Standby Mode. When in
Signal Sense Standby Mode and the RSP-1576MKII detects audio on
Signal Sense Input, the unit will automatically power on. To disable this
function, select the DISABLE option which is the factory default setting.
NOTE: When the RSP-1576MKII enters standby mode via the remote
control, the Signal Sense function will not operate until the unit detects
the audio has stopped for the minimum 10 minute time-out period. This
prevents the unit from immediately powering back on if there is still
active audio playing.
NOTE: When the SIGNAL SENSE INPUT function is activated, the
RSP-1576MKII will consume additional power in signal sense standby
mode.
NOTE: Due to local power consumption regulations the Signal Sense
function is not available in all markets.
NETWORK CONFIGURATION: Sets the network configuration for the unit. In
most systems, set the IP ADDRESS MODE to DHCP. This setting will allow
your router to assign an IP address to the RSP-1576MKII automatically. If
your network uses fixed IP addresses, set the IP ADDRESS MODE to Static. A
fixed or STATIC IP address requires manually entering the IP Address, Subnet
Mask, Gateway, and DNS in the IP ADDRESS CONFIGURATION sub menu.