Note!
The following table describes in detail the codes mentioned in the examples
l
for commissioning!
Do not change codes, the meaning of which is unknown to you! All codes
l
are described in detail in the System Manual.
How to read the code table
Column
Abbreviation
Code
Cxxxx
*
v
s
(A)
uSEr
Name
Lenze
à
Selection
1
IMPORTANT
L

The most important codes for commissioning

Meaning
Code Cxxxx
1
Subcode 1 of Cxxxx
2
Subcode 2 of Cxxxx
Parameter value of the code is the same in all parameter sets
Keypad E82ZBC
Keypad XT EMZ9371BC
Keypad E82ZBC
Keypad XT EMZ9371BC
Code, subcode or selection are only available when using an Application−I/O
With Lenze setting the code is available in the USER−menu
Name of the code
Lenze setting (value at delivery or after restoring the delivery state with C0002)
Further information can be obtained from "IMPORTANT"
{%}
99 Min. value
Brief, important explanations
EDK82EV222 DE/EN/FR 10.1
Commissioning
The parameter value of a code can be different in
l
every parameter set.
Parameter value accepted immediately (ONLINE)
l
Changed parameters will be accepted after pressing
v
Changed parameters will be accepted after pressing
T V
Changed parameters will be accepted after pressing
v
if the controller is inhibited
Changed parameters will be accepted after pressing
T V
if the controller is inhibited
{unit}
Max. value
7