Lenze 8200 vector Instructions De Montage page 115

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1
Status display
Display
Meaning
d
Ready for operation
c
Pulse inhibt active
b
Adjusted current limitation is exceeded in motor−mode or
generator−mode
e
Warning active
a
Fault active
2
Bargraph display
Value set under C0004 in %
(Lenze setting: Controller load C0056)
3
Function bar 1
Function Meaning
j
Setpoint selection via
g
Display function:
User menu, memory location 1 (C0517/1), display
l
Display active parameter set
l
f
Code selection
k
Subcode selection
i
Change of parameter value of a (sub)code
h
Display of values longer than 5 digits
H: higher value locations
L: lower value locations
4
Function bar 2
Function Meaning
m
Select parameter set 1 ... parameter set 4 for changing
n
Selection of system bus (CAN) devices
o
Select menu
The user menu is active after mains switching
L
Using the keypad E82ZBC − Parameter setting
yz
EDK82EV222 DE/EN/FR 10.1
Commissioning
Explanation
Power outputs inhibited
C0022 (motor mode) or C0023 (generator mode)
Display range: − 180 % ... + 180 % (every bar = 20 %)
Explanation
Not possible when password protection is active (display
=
)
"loc"
Active after every main connection
Display of active code in 4−digit display
Display of active subcode number in 3−digit display
Display of current value in 5−digit display
Display
"HI"
Display
"lo"
Explanation
5
Display, e.g. PS
2
(
)
l
The parameter sets can only be activated via digital
l
signals (configuration with C0410)
The selected device can be parameterised by the current
drive
r
= function active
List of codes in the user menu (C0517)
user
List of all codes
all
Only specific codes for bus function modules,
funci
e.g. INTERBUS, PROFIBUS−DP and LECOM-B
7
6
7
8
115

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Edk82ev222

Table des Matières