Function Module (Optional); Mounting - Lenze 8200 vector Instructions De Montage

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6

Function module (optional)

Mounting

Important notes
The basic controller version is not equipped with control terminals. The controllers can be
equipped with control terminals by using different I/O function modules for the FIF
interface.
Dismount the function module only if it is absolutely necessary (e.g. when the controller is
replaced).
The pin strip which is used to connect the function module is part of the contact system
of the controller. It has not been designed for repeated connection and disconnection of
the function module.
Mounting of function modules

OFF
3 min
1. Disconnect the controller from the mains and wait for at least 3 minutes!
2. Remove the FIF protection cover 0 and keep it.
3. Remove the protection cover 1 of the function module.
4. Plug the function module 2 onto the FIF interface.
5. Plug the plug connector 3 into the contact bank of the function module until it is
snapped into place.
6. For wiring see Mounting Instructions for the function module.
106
EDK82EV222 DE/EN/FR 10.1
ƒ
−25−
8200vec007
L

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Edk82ev222

Table des Matières