Lenze 8200 vector Instructions De Montage page 141

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Code
No.
Name
C0007
Fixed
v
configuration of
digital inputs
uSEr
C0007
v
uSEr
(cont.)
L
The most important codes for commissioning
Possible settings
Lenze
Selection
0
E4
0
CW/CCW
1
CW/CCW
2
CW/CCW
3
CW/CCW
4
CW/CCW
5
CW/CCW
6
CW/CCW
7
CW/CCW
8
CW/CCW
9
CW/CCW
10
CW/CCW
E4
11
CW/CCW
12
CW/CCW
13
CW/CCW
14
CCW/QSP
15
CCW/QSP
16
CCW/QSP
17
CCW/QSP
18
CCW/QSP
19
CCW/QSP
EDK82EV222 DE/EN/FR 10.1
E3
E2
E1
DCB
JOG2/3
JOG1/3
PAR
JOG2/3
JOG1/3
QSP
JOG2/3
JOG1/3
PAR
DCB
JOG1/3
QSP
PAR
JOG1/3
DCB
TRIP set
JOG1/3
PAR
TRIP set
JOG1/3
PAR
DCB
TRIP set
QSP
PAR
TRIP set
QSP
TRIP set
JOG1/3
TRIP set
UP
DOWN
E3
E2
E1
DCB
UP
DOWN
PAR
UP
DOWN
QSP
UP
DOWN
CW/QSP
DCB
JOG1/3
CW/QSP
PAR
JOG1/3
CW/QSP
JOG2/3
JOG1/3
CW/QSP
PAR
DCB
CW/QSP
PAR
TRIP set
CW/QSP
DCB
TRIP set
Commissioning
IMPORTANT
Change under C0007 will be copied
to the corresponding subcode of
C0410. Free configuration under
C0410 sets C0007 = 255!
l
CW/CCW = CW rotation/CCW
rotation
DCB = DC injection brake
l
QSP = Quick stop
l
l
PAR = Parameter set changeover
ó
(PAR1
PAR2)
– PAR1 = LOW, PAR2 = HIGH
– The terminal must be assigned
to the function "PAR" in PAR1
and PAR2.
– Configurations with "PAR" are
only allowed if C0988 = 0
TRIP set = external fault
l
JOG1/3, JOG2/3 = Selection of
l
fixed setpoints
– Activate JOG1:
JOG1/3 = HIGH; JOG2/3 = LOW
– Activate JOG2:
JOG1/3 = LOW; JOG2/3 = HIGH
– Activate JOG3:
JOG1/3 = HIGH; JOG2/3 = HIGH
l
UP/DOWN = motor potentiometer
functions