80 and 450 s. You can also set the working time and pause time for this pro-
gram to between 1 and 30 seconds each.
1. Place the electrodes on your chosen area (for positioning suggestions, see
section "8.4 Information on electrode positioning") and connect them to the
device.
2. Select the EMS 34 program as described in section "8.2 Starting use" (step 3
to step 5).
3. Use the
/
setting buttons to select your preferred working duration
("on time") and press theENTER button to confirm your selection.
4. Use the / setting buttons to select your preferred pause duration ("o time")
and press theENTER button to confirm your selection.
5. Use the / setting buttons to select your preferred pulse frequency and
press the ENTER button to confirm.
6. Use the / setting buttons to select your preferred pulse width and press
the ENTER button to confirm.
7. Use the / setting buttons to select your preferred treatment time and press
the ENTER button to confirm your selection.
8. Use the left and right / setting buttons as needed for
select your preferred pulse intensity.
EMS 35 program
The EMS 35 program is a burst program that you can also customise. Various
pulse sequences run in this program. Burst programs are suitable for all areas
of application to be treated with changing signal patterns (to minimise the level
of becoming accustomed to the treatment). In this program, you can set the
pulse frequency to between 1 and 150 Hz and the pulse width to between 80
and 450 µs. You can also set the working time and pause time for this program
to between 1 and 30 seconds each.
1. Place the electrodes on your chosen area (for positioning suggestions, see
section "8.4 Information on electrode positioning") and connect them to the
device.
2. Select the EMS 35 program as described in section "8.2 Starting use" (step 3
to step 5).
3. Use the
/
setting buttons to select your preferred working duration
("on time") and press theENTER button to confirm your selection.
4. Use the / setting buttons to select your preferred pause duration ("o time")
and press theENTER button to confirm your selection.
and
© Copyright Gebrauchs.info
5. Use the / setting buttons to select your preferred pulse frequency and
press the ENTER button to confirm.
6. Use the / setting buttons to select your preferred pulse width and press
the ENTER button to confirm.
7. Use the / setting buttons to select your preferred treatment time and press
the ENTER button to confirm your selection.
8. Use the left and right / setting buttons as needed for
select your preferred pulse intensity.
8.9 Doctor's function
The Doctor's function is a special setting to allow you to access your personal
program even more easily and directly. Your individual program settings are
instantly recalled and activated when the device is switched on. You may wish
to set this individual program, e.g. following advice from your doctor.
Setting the Doctor's function
• Select your program and the corresponding settings as described in sec-
tion "8.2 Starting use".
to
• At the start of the stimulation treatment, the pulse intensity of
is set to 00 by default. No pulses are sent to the electrodes yet. Before
setting your preferred pulse intensity using the intensity setting buttons,
press and hold the
function is confirmed by a long acoustic signal.
• When you switch the device on again, the program you saved using the
Doctor's function will automatically be opened straight away.
Deleting the Doctor's function
To clear the device again and to re-enable access to other programs, press
and hold the
button again for approx. 5 seconds. To do this, the
pulse intensity of
and
function is confirmed by a long acoustic signal.
8.10 Therapy memory
The EM 1 R records the treatment time. To access the therapy memory, switch
the device on using the ON/OFF
button for 5 seconds. The elapsed treatment time appears in the display. The
top two numbers represent the minutes; the hours are shown below. To reset
the treatment time, press and hold the
batteries are replaced, the therapy memory is automatically reset. Press the
32
button for 5 seconds. Saving to the Doctor's
must be set to 00. Deletion of the Doctor's
button and press and hold the
button for 5 seconds. When the
and
to
and