Designation
4 x adhesive electrodes
(50 x 100 mm)
13. TECHNICAL SPECIFICATIONS
Name and model
EM 1 R
Type
EM 49
Output waveform
Biphasic rectangular pulses
Pulse duration
50–450 µs
Pulse frequency
1–150 Hz
Output voltage
max. 100 Vpp (at 500 Ohm)
Output current
max. 200 mApp (at 500 Ohm)
Voltage supply
3 x AAA batteries (LR03)
Treatment time
adjustable from 5 to 100 minutes
Intensity
adjustable from 0 to 50
Operating conditions
5°C to 40°C (41°F to 104°F) at a relative
humidity of 15% to 90%
Storage conditions
0°C to 40°C (32°F to 104°F) at a relative
humidity of up to 90%
Transport conditions
−25°C to 70°C (−4°F to 140°F) at a relative
humidity of up to 90%
Dimensions
6.3 x 13.2 x 2.7 cm (including belt clip)
Weight
83 g (including belt clip, excluding batteries),
117 g (including belt clip and batteries)
Altitude limit for use
3,000 m
Maximum permissible
700 to 1060 hPa
atmospheric pressure
The serial number is located on the device or in the battery compartment.
Item number and/or order number
Mat. no. 725.649 (Art. no. 661.01)
© Copyright Gebrauchs.info
Note: If the device is not used according to the instructions specified, perfect
functionality cannot be guaranteed!
We reserve the right to make technical changes to improve and develop the
product.
This device conforms with the European standards EN 60601-1 and
EN 60601-1-2 (compliance with IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11) and is subject
to particular precautions with regard to electromagnetic compatibility. Please
note that portable and mobile HF communication systems may interfere with
this device.
For more details, please contact Customer Services at the address indicated.
The device complies with the respective national provisions.
For this device, a functional test and instruction in accordance with the Ger-
man Medical Devices Operator Ordinance (MPBetreibV) is not required. It is
also not necessary to carry out safety checks in accordance with the German
Medical Devices Operator Ordinance (MPBetreibV).
Notes on electromagnetic compatibility
• The device is suitable for use in all environments listed in these instructions
for use, including domestic environments.
• The device may not be fully usable in the presence of electromagnetic dis-
turbances. This could result in issues such as error messages or the failure
of the display/device.
• Avoid using this device directly next to other devices or stacked on top of
other devices, as this could lead to faulty operation. If, however, it is neces-
sary to use the device in the manner outlined above, this device as well as
the other devices must be monitored to ensure they are working properly.
• The use of accessories other than those specified or provided by the manu-
facturer of this device can lead to an increase in electromagnetic emissions
or a decrease in the device's resistance to electromagnetic interference;
this can result in faulty operation.
• Failure to comply with the above could impair the performance of the de-
vice.
• Keep portable RF communication devices (including peripheral equipment,
such as antenna cables or external antennas) at least 30 cm away from all
device parts, including all cables included in delivery.
14. GUARANTEE / SERVICE
More information on the guarantee and guarantee conditions can be found in
the guarantee leaflet supplied.
35