3. STORAGE

The machine is stored by the Manufacturer or Technician.

4. INSTALLATION

The machine must only be installed by the Technician.
When the machine is being installed, the Techni-
cian must replace the water in the hydraulic cir-
cuits.
The machine's support base must be perfectly flat,
not incline by more than 2° and have no irregulari-
ties.
The electrical system must be equipped with a
suitable residual-current device in compliance with
current laws and safety regulations.

5. COMMISSIONING

The machine must only be commissioned by the Technician.

6. OPERATION

6.1 Safety precautions

Carefully read the instructions provided in chapter
"I. SAFETY PRECAUTIONS" on page 33.

6.2 Emissions

Vibrations
In operating conditions that comply with the indications of
correct use provided in this manual, any detected vibrations
do not give rise to dangerous situations.
Sound emissions
The noise level emitted by the machine is on average lower
than 70 dB; therefore, the use of personal protective equip-
ment to prevent hearing damage is not compulsory.
If the machine emits any unusual sounds, the Technician
must be notified.
Electromagnetic environment
The machine is designed to work properly in any industrial
electromagnetic environment, falling within the Emission and
Immunity limits provided by current standards.
44
216
of

6.3 Turning the machine on and off

During the machine's heating-up phase (roughly
20 minutes), the negative pressure valve will re-
lease steam for a few seconds until the valve closes.
Do not open the gas mains when the heating unit is empty.
If the machine is inactive for longer than a week,
the Technician must replace 100% of the water in-
side the hydraulic circuits.

Electric heating for the AL version

6.3.1
Before starting the machine, make
sure that the level of water in the
heating unit is higher than the min-
imum level indicated on the water
level window (1).
If there is no water (first installation
or after heating unit maintenance),
the heating unit must be filled in ad-
vance in order to prevent the heating
element from overheating.
Proceed as follows:
Switch
• Open the water mains valve.
• Using the manual fill function, fill the heating unit with
water until the optimal level is restored.
• Turn the switch to position "1" and wait for
the machine to warm up completely.
Power switch
• Open the water mains valve.
• Turn the power switch to position "1" (electricity is sup-
plied to the pump to automatically fill up the appliance's
heating unit and steam heating unit) and wait for the
heating unit to be automatically filled with
water.
• Turn the main switch to position "2" (full
electricity is supplied, including to the heat-
ing element in the heating unit) and wait
for the machine to warm up completely.
6.3.2
Electric heating for the AEP and
SAE versions
Press the machine's power
switch (2).
The slow flashing warning
light (3) indicates that the
water is being filled up.
A steady warning light indi-
cates that the standard water
level has been reached in the
heating unit.