Manuel de configuration du FC 300
Bit 09, Local operation/bus control:
Bit 09 = '0': [STOP/RESET] is activate on the control unit or
converter via serial communication. Bit 09 = '1' It is possible to control the frequency converter via the fieldbus/ serial communication.
Bit 10, Out of frequency limit:
Bit 10 = '0': The output frequency has reached the value in Par. 4-11
= "1": The output frequency is within the defined limits.
Bit 11, No operation/in operation:
Bit 11 = '0': The motor is not running. Bit 11 = '1': The frequency converter has a start signal or the output frequency is greater than 0 Hz.
Bit 12, Drive OK/stopped, autostart:
Bit 12 = '0': There is no temporary over temperature on the inverter. Bit 12 = '1': The inverter stops because of over temperature but the unit does not
trip and will resume operation once the over temperature stops.
Bit 13, Voltage OK/limit exceeded:
Bit 13 = '0': There are no voltage warnings. Bit 13 = '1': The DC voltage in the frequency converter's intermediate circuit is too low or too high.
Bit 14, Torque OK/limit exceeded:
Bit 14 = '0': The motor current is lower than the torque limit selected in Par. 4-18
courant
is exceeded.
Bit 15, Timer OK/limit exceeded:
Bit 15 = '0': The timers for motor thermal protection and thermal protection are not exceeded 100%. Bit 15 = '1': One of the timers exceeds 100%.
N.B.!
All bits in the STW are set to '0' if the connection between the Interbus option and the frequency converter is lost, or an internal
communication problem has occurred.
Local control
in Par. 3-13
Vit. mot., limite infér. [tr/min]
Limite courant
MG.33.BB.04 - VLT® est une marque déposée Danfoss
7 Installation mécanique - Châssis de taille D,
Type référence
is selected. You cannot control the frequency
Vit. mot., limite supér. [tr/min]
or Par. 4-13
. Bit 14 = '1': The torque limit in Par. 4-18
E et F
. Bit 10
Limite
7
131