EGO AURA-R2 RMR1500E Mode D'emploi page 22

Table des Matières
TROUBLESHOOTING
EN
Error Codes List
The list below shows a number of error codes shown on the LCD screen of the product and your EGO Connect
the same code appears frequently.
Error code
1000
1001
1002
1003
1004
1005
1006
22
ROBOTIC MOWER — RMR1500E/RMR3000E/RMR6000E
Description
Electronic systems self-test error
Mowing motor self-test failed
Mowing motor overload
Mowing motor failure
Mowing motor blocked
Mowing motor overload
Mowing motor supply voltage too low
Solution
Self test of all electrical systems returned an error.
1. Power off the mower, and restart.
If the error persists, contact EGO support for remote assistance.
Self test of mowing motor returned an error.
1. Power off the mower, and restart.
If the error persists, contact your EGO service provider.
Mowing motor has a spike in power demand.
1. Remove hard objects in the mowing area such as stones, branches
and toys.
2. Press the Start + OK buttons on the mower, or select Clear Error in
the app.
3. If the error persists, power off the mower and restart.
If the error persists, contact your EGO service provider.
Mowing motor power supply is abnormal.
1. Power off the mower and restart.
If the error persists, contact your EGO service provider.
Mowing motor detected abnormally high power demand.
1. Check and adjust the cutting height setting. Grass longer than 9 cm
should be cut to a manageable level for the mower to maintain.
2. Press the Start + OK buttons on the mower, or select Clear Error in
the app.
3. If the error persists, power off the mower, check the cutting disk for
obstructions.
NOTE: High motor usage can stress parts and lead to reduced service life.
If this error persists, contact your EGO service provider.
Mowing motor stalled.
1. Check and adjust the cutting height setting. Grass longer than 9 cm
should be cut to a manageable level for the mower to maintain.
2. Press the Start + OK buttons on the mower, or select Clear Error in
the app.
3. If the error persists, power off the mower, check the cutting disk for
obstructions.
NOTE: High motor usage can stress parts and lead to reduced service life.
If this error persists, contact your EGO service provider.
Mowing motor power supply is abnormal.
1. Power off the mower and restart.
If the error persists, contact your EGO service provider.
app. Contact EGO service center if
TM