GENERAL INFORMATIONS

GENERAL INFORMATIONS
GENERAL INFORMATIONS
GENERAL INFORMATIONS
GENERAL INFORMATIONS
GENERAL SPECIFICATIONS
GENERAL SPECIFICATIONS
GENERAL SPECIFICATIONS
GENERAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Case: PC-ABS black color; self-extinguishing degree: V-0
Case
Case
Case
Case
according to UL 746C.
Front protection
Front protection
Front protection
Front protection
Front protection - designed and tested for IP 65 (*) and
NEMA 4X (*) for indoor locations (when panel gasket is
installed).
(*) Test were performed in accordance with CEI 70-1 and
NEMA 250-1991 STD.
Rear terminal block: screw terminals (screw M3, for
Rear terminal block
Rear terminal block
Rear terminal block
Rear terminal block
cables from φ 0.25 to φ 2.5 mm
2
or from AWG 22 to AWG
14 ) with connection diagrams and safety rear cover.
Weight
Weight
Weight
Weight
Weight:
360 g (0.8 lb) for TKS
450 g (1 lb) for MKS.
Power supply
Power supply
Power supply:
Power supply
Power supply
- 100V to 240V AC 50/60Hz (-15% to + 10% of the
nominal value).
- 24 V AC/DC (+ 10 % of the nominal value).
Power consumption: 5.5 W max.
Power consumption
Power consumption
Power consumption
Power consumption
Insulation resistance
nsulation resistance
nsulation resistance
nsulation resistance: > 100 MΩ according to
nsulation resistance
IEC 1010-1.
Dielectric strength
Dielectric strength
Dielectric strength
Dielectric strength
Dielectric strength: 2300 V rms according to
EN 61010-1.
Display updating time
Display updating time: 500 ms.
Display updating time
Display updating time
Display updating time
Sampling time:
Sampling time:
Sampling time:
Sampling time:
Sampling time:
250 ms for linear inputs
500 ms for TC and RTD inputs.
Control output updating time:
Control output updating time:
Control output updating time:
Control output updating time:
Control output updating time:
250 ms for linear inputs
500 ms for TC and RTD inputs.
Control output resolution
Control output resolution
Control output resolution: 0.1% of the span.
Control output resolution
Control output resolution
Instrument resolution
Instrument resolution
Instrument resolution
Instrument resolution: 30000 counts.
Instrument resolution
Accuracy
Accuracy
Accuracy
Accuracy
Accuracy: + 0.2% f.s.v.. + 1 digit @ 25 °C and nominal
power supply voltage.
Common mode rejection: 120 dB at 50/60 Hz.
Common mode rejection
Common mode rejection
Common mode rejection
Common mode rejection
Normal mode rejection:
Normal mode rejection:
Normal mode rejection:
Normal mode rejection: 60 dB at 50/60 Hz.
Normal mode rejection:
Electromagnetic compatibility and safety require-
Electromagnetic compatibility and safety require-
Electromagnetic compatibility and safety require-
Electromagnetic compatibility and safety require-
Electromagnetic compatibility and safety require-
ments
ments
ments: This instrument is marked CE.
ments
ments
Therefore, it is conforming to council directives 89/336/
EEC (reference harmonized standard EN 50081-2 and
EN 50082-2) and to council directives 73/23/EEC and
93/68/EEC (reference harmonized standard EN 61010-1).
Installation category
Installation category
Installation category
Installation category: II
Installation category
Pollution degree
Pollution degree
Pollution degree
Pollution degree
Pollution degree: 2
XKSser1-B0.PMD
25
Temperature drift
Temperature drift: (CJ excluded)
Temperature drift
Temperature drift
Temperature drift
< 200 ppm/°C of span for mV and TC ranges 1, 3, 5, 7, 21,
22, 23, 25.
< 300 ppm/°C of span for mA/V
< 400 ppm/°C of span for RTD range 12, 30 and TC ranges
0, 2, 4, 6, 24.
< 500 ppm/°C of span for RTD range 11 and TC ranges 8, 9,
26, 27.
< 800 ppm/°C of span for RTD range 29 and TC ranges
10,28.
Operative temperature
Operative temperature
Operative temperature: from 0 to 50 °C.
Operative temperature
Operative temperature
Storage temperature : -20 to +70 °C
Storage temperature :
Storage temperature :
Storage temperature :
Storage temperature :
Humidity
Humidity
Humidity
Humidity: from 20 % to 85% RH, non condensing.
Humidity
Altitude: This product is not suitable for use above 2000m
Altitude
Altitude
Altitude
Altitude
(6562ft)
Protections
Protections:
Protections
Protections
Protections
1) WATCH DOG circuit for automatic restart.
2) DIP SWITCH for protection against tampering of
configuration and calibration parameters.
M A I N T E N A N C E
M A I N T E N A N C E
M A I N T E N A N C E
M A I N T E N A N C E
M A I N T E N A N C E
1) REMOVE POWER FROM THE POWER SUPPLY
TERMINALS AND FROM RELAY OUTPUT
TERMINALS
2 ) Remove the instrument from case.
3 ) Using a vacuum cleaner or a compressed air jet (max.
3 kg/cm
2
) remove all deposit of dust and dirt which may
be present on the louvers and on the internal circuits
trying to be careful for not damage the electronic
components.
4) To clean external plastic or rubber parts use only a
cloth moistened with:
- Ethyl Alcohol (pure or denatured) [C
- Isopropil Alcohol (pure or denatured) [(CH
or
- Water (H
O)
2
5 ) Verify that there are no loose terminals.
6 ) Before re-inserting the instrument in its case, be sure
that it is perfectly dry.
7 ) re-insert the instrument and turn it ON.