GEARMOTOR TECHNICAL SPECIFICATIONS
Description
Product type
Technology used
Maximum torque
Nominal torque
No-load speed
Nominal torque speed
Operating limits
Maximum power consumption (W)
Maximum operating frequency
Operating temperature (min/max
°C)
Protection rating
Dimensions (mm)
Weight (kg)
TECHNICAL CHARACTERISTICS OF THE CONTROL UNIT
Description
Mains power supply
Maximum power input
Emergency power supply
Maximum motor current
Stand-By mode
Standby all (W)*
Warning light output
OGI/electric lock output
STOP input
Work time
Pause time
Discharge time
Leaf opening delay
Leaf closing delay
Max length of cables
Operating temperature
Protection rating
Dimensions (mm)
Weight (kg)
*
In the calculation of power consumption in Standby Mode, the energy consumption of accessories has not been considered. Please
refer to the respective instructions for the consumption of these accessories such as external receivers or devices connected to the
power outputs, if present.

11 - TECHNICAL SPECIFICATIONS

RIVA200M
Electromechanical gear motor for automatic gates and doors
24 V
motor, helical gear reducer; mechanical release
250 Nm
120 Nm
1,25 RPM
1,00 RPM
Its structural characteristics make it suitable for weights up to 200 kg or door lengths up to 2,3 metres and
opening angles up to 180°.
120
60 cycles/hour
-20°C ... +55°C
IP67
230 x 206 x 88 (including foundation box)
15
Technical specification
230 Va ±10% 50 - 60 Hz; fuse: 1A type T
170 W
Pre-set for PRS100 buffer batteries and Solekit solar kit
3 A (with "level 6" amperometric device intervention)
Factory-set to automatic after 5 minutes from the end of main functions
< 0,25
for 24 V c warning lights, maximum power 25 W (the voltage may vary between 16 V and 33 Vc)
for 24 V c lamps, maximum power 5 W (the voltage may vary between 16 V and 33 V c) or for 12 V a
electric locks, 15 VA
for NC contacts or 8.2 kΩ fixed resistor +/– 25%
measured automatically
settable
settable
settable
measured automatically
power supply: 30 m
Solekit solar kit power supply: 3 m
motors: 10 m
other inputs/outputs: 30 m
warning light: 10 m
OGI: 30 m
electric lock: 10 m
antenna: 20 m (recommended below 3 m)
from –20°C to +55°C
IP 54 (with container intact)
310 x 232 x H 122
4,1
Table 21
Table 22
ENGLISH – 39