2
wait a few seconds for the control unit to finish learning the de-
vices
3
on the control unit ("Figure 34") at the end of the learning pro-
cess, the 'Stop' LED must remain lit and the 'L2' LED must
light up. The ECSbus LED must flash once per second. If the
'L2' LED flashes = error (see chapter TROUBLESHOOTING
GUIDE.
34
Flash
OGI
Flash
OGI
M
M
M
M
M
M
M
Flash
OGI
M
M
M
M
5 4
MOTOR TYPE SELECTION
1
The control unit is equipped with a selector (A) ("Figure 35") that
allows you to specify the type of motor connected to the control
unit (see "Table 7").
a
Take great care when setting the selector according to
the motor type as specified in Table 7
a
The motor selector must be set before activating the
learning of the mechanical stop positions; any config-
uration not shown in the table is not permitted
a
If it is necessary to change the selector configuration
following a change in motor type, the opening and
closing angles of the gate leaves must be memorised
again (see chapter "Storing the opening and closing
angles of the gate leaves")
35
22 – ENGLISH
ECSbus Stop
Sbs
Open
BUS
Stop
Sbs
Open
ECSbus Stop
Sbs
Open
O
N
1
2 3 4 5
SELECTING THE MOTOR TYPE
Motor type
RIVA 200
ARIA 200
ARIA 400
MAESTRO 200
MAESTRO 300
LEGGIO 300
5 5
STORING THE OPENING AND CLOSING
ANGLES OF THE GATE LEAVES
Once the motor type has been selected, the control unit must be al-
lowed to recognise the opening angles of the leaves. During this phase,
the opening angle of the leaves is detected from the mechanical closing
stop to the mechanical opening stop. Fixed and sufficiently robust me-
chanical stops must be present.
1
Manually unlock the gear motors (A) and move the leaves
halfway so that they are free to move in opening and closing;
then lock (B) the motors ("Figure 36")
36
180°
A
A
Table 7
Motor selector
1
2 3 4 5
O
N
1
2 3 4 5
O
N
1
2 3 4 5
O
N
1
2 3 4 5
O
N
1
2 3 4 5
O
N
1
2 3 4 5
O
N
180°