– If the opening movement is controlled by a fire-sensing sys-
tem, make sure that any windows larger than 200 mm are
closed using the control elements.
– Prevent and avoid any form of entrapment between the mov-
ing and fixed parts during the manoeuvres.
– Permanently affix the label concerning the manual manoeu-
vre near its actuating element.
– After installing the drive motor, make sure that the mecha-
nism, protective system and all manual manoeuvres function
properly.
– Doors and vertical gates require an anti-fall function or device
– For drive motors that allow for accessing unprotected mov-
ing parts once they have been installed, such parts must be
installed at least 2.5 m above the floor or other surface from
which they can be accessed.
– Make sure to avoid any entanglements due to the opening
movement of the driven part.
– After the installation, make sure that the mechanism is cor-
rectly adjusted and that the protection system and the man-
ual release device (if present) work properly.
The devices in the RIVA kit and other optional accessories are part of
the Nice Home automation system and are designed to automate a
swing gate for residential use.
The kit consists of two electromechanical gear motors in direct current
at 24 V
; they are equipped with a mechanical release with key that
allows the gate to be moved manually in the event of a power failure.
A control unit manages the operation of the entire automation system.
The control unit is connected to the photocells via the ECSbus system
(a single cable with two electrical conductors).
The control unit can be powered by the mains (230 V~) or by the SOL-
EKIT photovoltaic system from the Nice Home range. When powered
by the mains, it can accommodate a backup battery (model PRS100
- not supplied) which ensures that the automation system can perform
certain operations in the hours following a power failure.
a
CAUTION! – Any use other than that specified herein or
in environmental conditions other than those stated in
this manual is to be considered improper and is strictly
forbidden!
This product complies with the criteria of the 'Standby' regu-
lation The product enters standby mode 5 minutes after com-
pleting one of its main functions when configured, or after 10
minutes if the product has not yet been configured.
Standby mode is set by default to STANDBY ALL with an activa-
tion time of 5 minutes
It also affects other functionalities listed below:
– The ECSbus output will be deactivated. If present, the power supply
to the auxiliary output will be disabled;
– accessories connected to the IBT4N connector will always be pow-
ered and total consumption will be affected;
– receivers connected to the SMTYPE connector will always be pow-
ered and total consumption will be affected.
Please refer to the specific chapters and technical specifications of the
accessory.
4 – ENGLISH
2 - PRODUCT DESCRIPTION AND INTENDED USE
Battery-operated appliances
– The appliance must be disconnected from the power supply
when removing the batteries.
– The batteries must be removed from the appliance prior to
its disposal.
– The batteries must be safely disposed of.
– If the batteries are not rechargeable, do not replace them
with rechargeable batteries.
Appliances with LED light
– Looking at LED lights from close up and for prolonged peri-
ods can cause dazzling. It may temporarily reduce eyesight
and cause accidents.
– Avoid looking at LEDs directly.
Appliances with radio device
– For transmitters: 433 MHz: ERP < 10 dBm - 868 MHz: ERP
< 14 dBm; for receivers: 433 MHz, 868 MHz.
This product can be equipped with an emergency power supply sys-
tem that guarantees operation even in the absence of the mains power
supply. The emergency power supply is via batteries, which must be
kept charged. The battery charging function is one of the main func-
tions of this product; the standby mode will only be activated when the
battery charging function is completed. Please refer to the instructions
of the emergency power supply system for the maximum time required
to fully charge the batteries.