5 6 2
Memorisation in "Mode 2"
During the procedure indicated in 'Table 9', the receiver stores only one button from those on the transmitter, assigning the function chosen by
the installer.
To memorise further buttons, repeat the procedure from the beginning for each button to be memorised.
The memory will occupy a single memory location and the command of the memorised button will be the one chosen by the installer in the 'Com-
mand list' of the automation control unit (see 'Table 5').
l
Before proceeding, you must clear the memory of the transmitter to be stored
MEMORISATION IN MODE 2 (AND EXTENDED MODE 2)
Description
Select the command you wish to store from those listed in the 'Table 5' and note down
the identification number (n).
Press and release the 'Radio' button a number of times equal to the number (n) that
identifies the selected command. The 'L1' LED flashes the same number of times.
On the transmitter being memorised
Hold down the button you want to memorise for 2 seconds If the memorisation is
successful, the 'L1' LED on the control unit flashes 3 times. (*2)
(*2) - If there are other transmitters to which you want to store the same command, repeat the sequence on the button of each additional trans-
mitter within 10 seconds. The procedure ends automatically when this time expires.
5 6 3
Memorising a new transmitter "near the receiver"
During the procedure indicated in 'Table 10', a new transmitter receives the same radio settings as a transmitter already stored in the control unit.
The procedure does not entail any direct action on the "Radio" button of the control unit, only the presence of the transmitter within the receiver's
reception range.
a
Wait 1 seconds between each step
MEMORISING A NEW TRANSMITTER "NEAR THE RECEIVER"
Description
On the new transmitter, press and hold the button you want to store Wait 7 seconds and
then release it
On the transmitter already memorised press slowly and release 3 times the memorised
button to be copied
On the new transmitter, press and hold the same button pressed at the start of the
procedure for 5 seconds (*2)
(*2) - If there are other transmitters to which you want to store the same command, repeat the sequence on the button of each
additional transmitter within 10 seconds The procedure ends automatically when this time expires
24 – ENGLISH
Symbols used
...(n)
Symbols used
x 7 sec.
Table 9
Table 10