Checking the set values
Before proceeding, check in Table 15 the parameter to be modified and the action to be performed.
Once you have identified the parameter you want to modify and the value to set it to, follow the commands to be given via the remote control in
sequence in the table row.
CHECKING THE SET VALUES
Parameter
Sequence for entering the display
Pause time
Pedestrian
opening
Press T1 and T2
simultaneously for at least
5 seconds and then release
them
Motor force
Step by Step
(SbS) function
Configuration
and Open input
OGI (Open
Gate Indicator)
function
Motor discharge
Press T1 and T3
1 and 2 when
simultaneously for at least
closing
5 seconds and then release
them
Motor discharge
1 and 2 on
opening
Press T1 and T4
simultaneously for at least
Standby
5 seconds and then release
them
*
Factory setting.
T1
T2
T3
T4
T1
... and hold it
down until the
flashing light
starts flashing.
T2
Within 3
Count the
seconds, press
flashes per
......
second and
compare the
result on the
right.
T3
T4
T1
Counting the
flashes of the
Set value
flashing light
1
10 seconds
2
20 seconds *
3
40 seconds
4
60 seconds
1
Gate opening at 0,7 m
Total door opening 1 m *
2
3
Half gate opening
4
Gate opening at 3/4
1
Low
2
Medium low *
3
Medium high
4
High
1
Open - Stop - Close - Stop
2
Open - Stop - Close - Open *
3
Open - Close - Open - Close
4
Open only
1
Opening (Open - Stop) *
2
Pedestrian opening (Step - Step)
OGI *
1
2
Courtesy light
3
Electric lock
Presence function (see paragraph '
4
Presence function'
None *
1
2
0,1 seconds (minimum)
3
0,2 seconds
4
0,3 seconds
5
0,4 seconds (average)
6
0,5 seconds
7
0,6 seconds
8
0,7 seconds (maximum)
1
None *
2
0,1 seconds (minimum)
3
0,2 seconds
4
0,3 seconds
5
0,4 seconds (average)
6
0,5 seconds
7
0,6 seconds
8
0,7 seconds (maximum)
1
Standby off
2
Standby in 60 seconds
3
Standby in 120 seconds
Standby in 300 seconds *
4
Table 15
ENGLISH – 31