Télécharger Imprimer la page

Nice Riva Serie Instructions Et Avertissements Pour L'installation page 65

Les langues disponibles

Les langues disponibles

2
on the control unit ("Figure 37") press and hold the 'P3' button
for at least 3 seconds; release the button when the motor starts
moving. Wait for the control unit to complete the memorisation
phase: motor M1 closes until mechanical stop, motor M2 closes
until mechanical stop, motor M2 and motor M1 open until me-
chanical stop in opening; M1 and M2 close completely.
37
a
If the first movement of one or both doors is not a
closing movement, press and release the 'P3' button
on the control unit ("Figure 37 ") to stop the memorisa-
tion phase and reverse the polarity of the motor(s) that
performed the opening, reversing the two blue (C) and
brown (D) wires ("Figure 38 ")
38
C
5 6
MEMORISATION OF A RADIO COMMAND
5 6 1
Memorisation in "Mode 1"
The control unit has a built-in radio receiver for transmitters MANDI4: before continuing, you must memorise the first transmitter in 'Mode 1'.
During the procedure indicated in 'Table 8', the receiver stores all the buttons on the transmitter, automatically assigning command 1 of the re-
ceiver to the 1st button, command 2 to the 2nd button, and so on.
The memorisation will ultimately occupy a single memory location and the command associated with each button will depend on the "List of
commands" present on the automation's control unit.
MEMORISATION IN MODE 1
Description
Press and hold the 'Radio' button on the control panel and wait for the 'L1' LED to light
up Release the 'Radio' button
On the transmitter being memorised
Press and hold any button for 3 seconds. If the memory is successful, the L1 LED flashes
3 times (*1)
(*1) - If there are other transmitters to be memorised, repeat the sequence on the transmitter within 10 seconds. The procedure ends automati-
cally when this time has elapsed.
D
M
M
a
If the first motor to move during closing is NOT M1,
press and release the 'P3' button on the control unit
("Figure 37 ") to stop the memorisation phase and re-
verse the motor terminals on the control unit ("Figure
39 ")
39
P3
M
M
M
M
Symbols used
Table 8
ENGLISH – 23
loading