4
position the lower shell where the cable passage tube arrives and mark the drilling points
5
drill the wall with a hammer drill using a 5 mm drill bit. Insert the 5 mm wall plugs into the holes
6
Pass the electrical cables through the holes and secure the lower shell with screws ("Figure 24")
24
7
Connect the electrical cable to the appropriate terminals on both the TX and RX (1) ("Figure 25"). Make the electrical connections accord-
ing to the required function and "Figure 27".
8
Reposition the inner shell (2), then the upper shell (3), securing it with the two screws (4). Finally, insert the cover and press gently to close
it ("Figure 25")
25
1
Ø 3,5 mm
˜
Led SAFE
2
3
5
4
ENGLISH – 15