Télécharger Imprimer la page

Siemens SIMATIC NET SINEC OS V2.4 Manuel De Configuration page 605

Pour scalance xch-300, xcm-300, xrh-300 et xrm-300

Publicité

13.3.2.5
Configuration de l'intervalle d'interrogation NTP
Pour configurer l'intervalle d'interrogation d'un serveur NTP, procédez comme suit :
Opé‐
ration
1
2
3
4
5
6
Exemple
localhost# config
Entering configuration mode terminal
localhost(config)# system time-sync ntp unicast-configuration ipv4
192.168.16.100 minpoll 8
localhost(config-ipv4-192.168.16.100)# maxpoll 12
localhost(config-ipv4-192.168.16.100)# commit
Commit complete.
localhost(config-ipv4-192.168.16.100)# end
localhost# show running-config system time-sync ntp unicast-
configuration ipv4 192.168.16.100 minpoll
system
time-sync
ntp
exit
exit
exit
localhost# show running-config system time-sync ntp unicast-
configuration ipv4 192.168.16.100 maxpoll
Command Line Interface (CLI) SINEC OS V2.4
Manuel de configuration, 10/2023, C79000-G8977-C498-07
Instruction
Passez en mode de configuration.
Configurez la plus petite valeur de l'intervalle
d'interrogation en secondes comme puissance
de 2.
Par défaut : 6
La valeur 6 correspond à 2
Configurez la plus grande valeur de l'intervalle
d'interrogation en secondes comme puissance
de 2.
Par défaut : 10
La valeur 10 correspond à 2
Validez les modifications.
Quittez le mode de configuration.
Contrôlez la configuration.
unicast-configuration ipv4 192.168.16.100
minpoll 8
exit
config
system time-sync ntp unicast-
configuration ipv4 { Adresse IP }
minpoll { 4 - 17 }
(64 secondes).
6
maxpoll { 4 - 17 }
10
(1024 secondes).
commit
end
show running-config system time-
sync ntp unicast-configuration
ipv4 {Adresse IP} minpoll
show running-config system time-
sync ntp unicast-configuration
ipv4 {Adresse IP} maxpoll
Réglages de la date/heure
13.3 NTP
Commande
605

Publicité

loading