Découverte et gestion de réseau
11.6 SNMP
Opé‐
ration
7
8
Exemple
localhost# config
Entering configuration mode terminal
localhost(config)# system management-services snmp usm local user
Userv3 auth md5 password
(<string, min: 8 chars, max: 255 chars>): **********
localhost(config-user-Userv3)# auth md5 password-confirm
(<string, min: 8 chars, max: 255 chars>): **********
localhost(config-user-Userv3)# commit
Commit complete.
localhost(config-user-Userv3)# end
localhost# show running-config system management-services snmp usm
local user Userv3 auth
system
management-services
snmp
exit
exit
exit
526
Instruction
Quittez le mode de configuration.
Contrôlez la configuration.
La clé localisée s'affiche à la place du mot de
passe configuré.
usm
local user Userv3
auth md5 localized-key "$8$tk2ukDr53pMp+..."
exit
exit
Commande
end
show running-config system
management-services snmp usm
local user { Nom } auth
Command Line Interface (CLI) SINEC OS V2.4
Manuel de configuration, 10/2023, C79000-G8977-C498-07