localhost# show running-config switch traffic-mirroring session 1
destination
switch
traffic-mirroring
session 1
exit
exit
exit
localhost# show interface ethernet1/1 vlan acceptable-frame
vlan acceptable-frame admit-all-frames
localhost# show interface ethernet1/2 vlan acceptable-frame
vlan acceptable-frame admit-all-frames
localhost# config
Entering configuration mode terminal
localhost(config)# switch mrp ring-id 1 ring-port1 ethernet1/1
localhost(config-ring-id-1)# ring-port2 ethernet1/2
localhost(config-ring-id-1)# commit
Commit complete.
localhost(config-ring-id-1)# end
localhost# show running-config switch mrp ring-id 1
switch
mrp
ring-id 1
exit
exit
exit
10.4.3
Surveillance de MRP
Ce paragraphe décrit les différentes méthodes de surveillance des anneaux MRP.
Command Line Interface (CLI) SINEC OS V2.4
Manuel de configuration, 10/2023, C79000-G8977-C498-07
destination port ethernet0/1
.
.
.
ring-port1 ethernet1/1
ring-port2 ethernet1/2
.
.
.