Starting System; Wire Connections - SELVA MARINE Moray 25 Manuel D'entretien

Table des Matières

Publicité

+
ELEC

STARTING SYSTEM

3
4
All manuals and user guides at all-guides.com
2
1
8-19
BATTERY
Refer to "GENERAL" in chapter 3.
FUSE
1. Check:
Fuse holder
No continuity → Check the fuse
holder leads.
Fuse holder leads
No continuity → Replace the fuse
holder.
Continuity → Check the fuse.
2. Check:
Fuse
No continuity → Replace.
Fuse rating:
12 V - 20 A
WIRE HARNESS
1. Check:
Continuity
No continuity → Replace.

WIRE CONNECTIONS

1. Check:
Wire connections
Poor connections → Properly con-
nect.
STARTER RELAY
1. Check:
Starter relay condition
Out of specification → Replace.
Checking steps:
Connect the tester between the starter
relay terminals as shown.
Tester positive lead 1 →
Starter relay terminal
Tester negative lead 2 →
Starter relay terminal
Check that there is no continuity
between the starter relay terminals.
Connect
the
tester
between the starter relay terminals.
E
and
battery

Publicité