EQUIPMENT REQUIRED
FOR INSTALLATION /
The authorised technical operator, in
order to perform the installation ope-
rations correctly, must respect the fol-
lowing requirements:
- 3 and 8 mm screwdriver
- Adjustable pipe wrench
- Gas use tools (hoses, gaskets etc.)
- Electrician's scissors
- Water use tools (hoses, gaskets etc.)
- 8 mm hex socket wrench
- Gas leak detector
- Tools for electric use (cables, termi-
nal blocks, industrial sockets etc.)
- 8 mm nut driver
- Complete installation set (gas etc.)
In addition to the tools listed,
an equipment lifting device is
required. This equipment must
comply with all the regulations rela-
ting to lifting equipment.
INDICATION
ON
RISK / Even though the rules for
"good manufacturing practice" and
the provisions of law which regulate
manufacturing and marketing of the
product have been implemented, "re-
sidual risks" still remain which, due
to the very nature of the appliance,
it has not been possible to eliminate.
These risks include:
RESIDUAL
ELECTROCUTION / This risks
remains when intervening on
live electrical and/or electronic devices.
RESIDUAL RISK OF BUR-
NING /
This risks remains
when unintentionally coming
into contact with materials at high
temperatures.
RESIDUAL RISK OF BURNS
DUE TO LEAKING OF MATE-
RIAL /
This risks remains
when unintentionally coming into
contact with materials at high tempe-
ratures. Containers that are too full of
liquids or solids that during warming
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
GENERAL AND SAFETY INFORMATION
RESIDUAL
RISK
OF
- 7 -
change morphology (changing from
a solid to a liquid), can, if used incor-
rectly, cause burns. During opera-
tions, the containers used must be
placed on easily visible levels.
RESIDUAL RISK OF CRU-
SHING LIMBS / This risk exists
where there is accidental contact
between the parts during positioning,
transportation, storage and assembly.
RESIDUAL RISK OF EXPLO-
SIONS / This risk remains
when:
• there is smell of gas in the room;
• appliance used in an atmosphe-
re containing substances which risk
exploding;
• using food in closed containers
(such as jars and cans), if they are
not suitable for the purpose.
RESIDUAL RISK OF FIRE /
This risk exists by flammable
liquids / material use / use of
the appliance as a fryer.
OPERATIONAL MODE FOR A
SMELL OF GAS IN THE ENVI-
RONMENT - see SECTION IMA-
GES - REFERENCES a)
If there is a smell of gas in
the environment, it is man-
datory to urgently implement
the procedures described below.
Immediately stop the gas supply
(Close the network tap, detail A).
Ventilate the room immediately.
Do not operate any electrical de-
vice in the environment (Detail
B-C-D).
Do not operate any device which
could produce sparks or flames
(Detail B-C-D).
Use a means of communication
that is external to the environment
where there is a smell of gas to
warn the relevant entities (electric-
ity operator and/or fire-fighters).
2.