Lenze Global Drive 8200 vector Instructions De Montage page 157

Convertisseur de fréquence
Masquer les pouces Voir aussi pour Global Drive 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Show/Hide Bookmarks
Display
1)
Keypad
PC
11
OC1
a
a
12
OC2
OC2
a
13
OC3
a
a
14
OC4
a
15
OC5
a
16
OC6
OC6
a
50
OH
a
-
OH
OH
e
53
OH3
a
54
OH4
a
203 PTC monitoring
OH51
1020 DC-bus overvoltage
OU
OU
c
75
Pr
a
72
Pr1
a
73
Pr2
a
77
Pr3
a
78
Pr4
a
79
Pr5
a
L
Troubleshooting and fault elimination
Fault
Cause
short-circuit
short-circuit
Excessive capacitive charging current of the motor
cable
Earth fault
Grounded motor phase
Excessive capacitive charging current of the motor
cable
Overload inverter during
Acceleration time (C0012) too short
acceleration or short circuit
Defective motor cable
Interturn fault in the motor
Overload controller during
Deceleration time too short (C0013)
deceleration
Controller overload in
Long and frequent overload periods
stationary operation
2
Motor overload (I
(
x t overload) Motor thermally overloaded by for instance
)
impermissible continuous current
frequent or too long acceleration processes
Heatsink temperature > +85
Ambient temperature T
°C
Heatsink temperature > +80
p
Heat sink very dirty
°C
°C
Impermissible high current or frequent and long
acceleration processes
PTC monitoring (TRIP)
Motor too hot because of impermissibly high
(only generated if C0119 = 1
current or frequent and long acceleration
processes
or 4)
or 4)
PTC not connected
Controller overtemperature
Controller inside too hot
Motor too hot because of impermissibly high
(only generated if C0119 = 2
current or frequent and long acceleration
processes
or 5)
or 5)
PTC not connected
g
Mains voltage too high
Braking operation
Earth leakage on the motor side
Faulty parameter transfer
All parameter sets are faulty
when using the keypad
Faulty transmission of PAR1
PAR1 is faulty.
when using the keypad
Faulty transmission of PAR2
PAR2 is faulty.
when using the keypad
Faulty transmission of PAR3
PAR3 is faulty.
when using the keypad
Faulty transmission of PAR4
PAR4 is faulty.
when using the keypad
Internal fault
> +60 °C
amb
EDK82EV903 DE/EN/FR 1.0
Error messages
Remedy
Find reason for short circuit; check motor cables
Check brake resistor
Use shorter/low-capacity motor cables
Check motor, check motor cable
Use shorter/low-capacity motor cables
Earth fault detection can be deactivated for checking
Increase acceleration time
Check drive selection
Check wiring
Check motor
Allow longer deceleration time
Check the external brake resistor selection
Check drive selection
Check drive selection
Check setting under C0120
Allow controller to cool down and ensure better
ventilation
Check ambient temperature
Clean heat sink
Check drive selection
Check load, if necessary replace sluggish, defective
bearings
Check drive selection
Connect PTC or switch-off monitoring (C0585=3)
Reduce controller load
Improve cooling
Check fan in the controller
Check drive selection
Connect PTC or switch-off monitoring (C0585=3)
Check voltage supply
Prolong deceleration times.
For operation with external brake resistor:
– Check dimensioning, supply and connection of
brake resistor
– Increase the deceleration times
Check motor cable and motor for earth fault (disconnect
motor from inverter)
It is absolutely necessary to repeat the data transfer or
load the factory setting before the controller is enabled.
Contact Lenze
79

Publicité

Table des Matières
loading

Table des Matières