Commissioning
Code table
Code
No.
Name
*
C0135
Controller control
word (parameter
channel)
C0138*
Process controller
setpoint 1
(PCTRL1-SET1)
C0140*
Additive frequency
setpoint
(NSET1-NADD)
C0141*
Setpoint normalised
56
Possible settings
Lenze
Selection
Bit
Assignment
1|0
JOG1, JOG2, JOG3 or C0046 (NSET1-JOG1/3,
NSET1-JOG2/3)
00
C0046 active
01
JOG1 (C0037) active
10
JOG2 (C0038) active
11
JOG3 (C0039) active
2
Current direction of rotation (DCTRL1-CW/CCW)
0
not inverted
1
inverted
3
Quick stop (DCTRL1-QSP)
0
not active
1
active
4
Stop ramp function generator (NSET1-RFG1-STOP)
0
not active
1
active
5
Ramp function generator input = 0 (NSET1-RFG1-0)
0
not active
1
active (deceleration to C0013)
6
UP function motor potentiometer (MPOT1-UP)
0
not active
1
active
7
DOWN function motor potentiometer (MPOT1-DOWN)
0
not active
1
active
8
Reserved
9
Controller inhibit (DCTRL1-CINH)
0
Controller enabled
1
Controller inhibited
10
TRIP set (DCTRL1-TRIP-SET)
11
TRIP reset (DCTRL1-TRIP-RESET)
0 Þ 1
Edge causes TRIP reset
13|12
Parameter set changeover (DCTRL1-PAR2/4,
DCTRL1-PAR3/4)
00
PAR1
01
PAR2
10
PAR3
11
PAR4
14
DC injection brake (MTCRL1-DCB)
0
not active
1
active
15
Reserved
0.00
-650.00
0.00
-650.00
0.00
-100.00
EDK82EV903 DE/EN/FR 1.0
{0.02 Hz}
650.00 The value set will be lost when switching
{0.02 Hz}
650.00
100.00 The value set will be lost when switching
{0.01 %}
IMPORTANT
•
Control via parameter channel. The most
important control commands are grouped as
bit commands.
•
C0135 cannot be changed using the keypad
RFG1 = Ramp function generator main setpoint
Sets "external error" (
E E E E E E E E r r r r
, LECOM No. 91)
(^LEERER MERKER)
the mains!
•
Selection if C0412/4 = FIXED-FREE
•
Display, if C0412/4 ≠ FIXED-FREE
j
•
Selection via function
of the keypad or
the parameter channel
•
Is added to main setpoint
•
Value is stored when switching the mains or
removing the keypad
the mains!
Only effective if C0127 = 1
Reference: C0011
L