Commissioning
Code table
Code
No.
Name
C0418*
Free configuration of
v
controller status
messages (2)
1 Bit 0
... ...
16 Bit 15
C0419
Free configuration of
v
v
analog outputs
analog outputs
1 X3/62 (AOUT1-IN)
2 (A) X3/63 (AOUT2-IN)
3 (A) X3/A4 (DFOUT1-IN)
70
Possible settings
Lenze
Selection
Output of digital signals to bus
255
Digital signal sources like C0415
255
Analog signal output to terminal
Analog signal source
0
0
Output frequency (MCTRL1-NOUT+SLIP)
2
1
Device utilisation (MCTRL1-MOUT) under C0014 = 2
or 3
Motor torque (MCTRL1-MACT) under C0014 = 4
3
2
Apparent motor current (MCTRL1-IMOT)
3
DC-bus voltage (MCTRL1-DCVOLT)
4
Motor power
5
Motor voltage (MCTRL1-VOLT)
6
1/output frequency (1/C0050) (MCTRL1-1/NOUT)
7
Output frequency with limits (NSET1-C0010...C0011)
8
Operation with process controller (C0238 = 0, 1):
Act. process controller value (PCTRL1-ACT)
Operation without process controller (C0238 = 2):
Output frequency without slip (MCTRL1-NOUT)
9
Ready for operation (DCTRL1-RDY)
10
TRIP fault message (DCTRL1-TRIP)
11
Motor is running (DCTRL1-RUN)
12
Motor is running / CW rotation (DCTRL1-RUN-CW)
13
Motor is running / CCW rotation (DCTRL1-RUN-CCW)
14
Output frequency = 0 (DCTRL1-NOUT=0)
15
Frequency setpoint reached (DCTRL1-RFG1=NOUT)
16
Q
threshold reached (PCTRL1-QMIN)
min
17
I
limit reached (MCTRL1-IMAX)
max
C0014 = -5-: Torque setpoint reached
18
Overtemperature (ϑ
19
TRIP or Q
or pulse inhibit (IMP) active
min
(DCTRL1-TRIP-QMIN-IMP)
20
PTC warning (DCTRL1-PTC-WARN)
21
Apparent motor current < current threshold
(DCTRL1-IMOT<ILIM)
22
Apparent motor current < current threshold and Q
threshold reached (DCTRL1-(IMOT<ILIM)-QMIN)
23
Apparent motor current < current threshold and RFG
1: Input = output (DCTRL1-(IMOT<ILIM)-RFG-I=0)
24
Warning motor phase failure (DCTRL1-LP1-WARN)
25
Minimum output frequency reached (PCTRL1-NMIN)
EDK82EV903 DE/EN/FR 1.0
IMPORTANT
6 V/12 mA/5.85 kHz ≡ C0011
3 V/6 mA/2.925 kHz ≡ Rated motor torque with
vector control (C0014 = 4), otherwise rated
active inverter current (active current/C0091)
3 V/6 mA/2.925 kHz ≡ Rated inverter current
6 V/12 mA/5.85 kHz ≡ DC 1000 V (400 V- mains
6 V/12 mA/5.85 kHz ≡ DC 380 V (230 V mains)
3 V/6 mA/2.925 kHz ≡ Rated motor power
4.8 V/9.6 mA/4.68 kHz ≡ Rated motor voltage
2 V/4 mA/1.95 kHz ≡ 0.5 × C0011
0 V/0 mA/4 mA/0 kHz ≡ f = f
6 V/12 mA/5.85 kHz ≡ f = f
6 V/12 mA/5.85 kHz ≡ C0011
Selection 9 ... 25 correspond to the digital
functions of the relay output K1 (C0008) or the
f
digital output A1 (C0117):
digital output A1 (C0117):
LOW = 0 V/0 mA/4 mA/ 0 kHz
LOW = 0 V/0 mA/4 mA/ 0 kHz
HIGH = 10 V/20 mA/10 kHz
HIGH = 10 V/20 mA/10 kHz
- 5 °C) (DCTRL1-OH-WARN)
max
Belt monitoring
Apparent motor current = C0054
pp
Current threshold = C0156
min
The assignment is mapped to the
– Controller status word 2 (C0151)
– FIF output word 2 (FIF-OUT.W2)
FIF output word 2 (FIF OUT.W2)
– Output word 1 in the CAN object 2
p
j
(CAN OUT2 W1)
(CAN-OUT2.W1)
All bits can be freely configured
All bits can be freely configured
The selection made under C0111 is
copied to C0419/1. A change of C0419/1
copied to C0419/1. A change of C0419/1
sets C0111 = 255!
DFOUT1: 50 ... 10 kHz
(C0010)
min
(C0011)
max
p
g
i
f h