Commissioning
Code table
Code
No.
Name
C0061*
Heat sink
temperature
C0070
Process controller
gain
C0071
Process controller
readjustment time
C0072
Differential
component of
process controller
C0074
Process controller
influence
C0077*
Gain I
controller
max
C0078*
Integral action time
I
controller
max
C0079
Oscillation damping
C0080
Service code
C0084
Motor stator
resistance
C0087
Rated motor speed
C0088
Rated motor current
C0089
Rated motor
frequency
C0090
Rated motor voltage
C0091
Motor cos j
C0092
Motor stator
inductance
C0093*
Type
C0094*
User password
C0099*
Software version
C0101
Acceleration times
main setpoint
(A)
1 C0012
2 T
1
ir
3 T
2
ir
4 T
3
ir
C0103
Deceleration times
main setpoint
(A)
1 C0013
2 T
1
if
3 T
2
if
4 T
3
if
52
Possible settings
Lenze
Selection
0
1.00
0.00
= P component not
active
100
10
0.0
0.0
= D component not
active
0.0
0.0
0.25
0.00
= P component not
active
130
12
2
0
0.0
0.0
1390
300
à
0.0
50
10
à
50
à
0.40
0.00
0.000
xxxy
0
= no password
protection
x.y
5.00
0.00
2.50
0.50
10.00
5.00
0.00
2.50
0.50
10.00
EDK82EV903 DE/EN/FR 1.0
{°C}
255 Only display
{0.01}
300.00
{1}
9999
= I component not active
{0.1}
5.0
{0.1 %}
100.0
{0.01}
16.00
{1 ms}
9990
= I component not active
{1}
80
{0.1 m Ω}
6500.0
{1 rpm}
16000
{0.1 A}
650.0
{1 Hz}
960
{1 V}
500
{0.1}
1.0
{0.01 mH}
200.00
{1}
9999 1 ... 9999 = Free access to user menu only
{0.02 s}
1300.00 Binary coding of the digital signal sources
1300.00 HIGH
{0.02 s}
IMPORTANT
If > +85 °C:
– Controller sets warning
O O O O H H H H
– Chopper frequency reduced if C0144 = 1
If > +90 °C:
– Controller sets TRIP
O O O O H H H H
Modifications only by Lenze service!
Depending on the controller
à
0.0 ... 2.0 x rated output current of the
controller
230 V with 230 V controllers,
à
400 V with 400 V controllers
Depending on the controller
à
Only display
xxx = Power taken from nameplate (e. g.
551 = 550 W)
y = Voltage class (2 = 240 V, 4 = 400 V)
Only display
x = Main version, y = Index
y
g
g
g
assigned under C0410/27 and C0410/28
i
d
d C0410/2
d C0410/28
determines active time pair
determines active time pair
C0410/27
C0410/28
active
LOW
LOW
C0012; C0013
LOW
T
1; T
ir
LOW
LOW
HIGH
HIGH
T
T 2 T 2
2; T
ir
HIGH
HIGH
HIGH
HIGH
T
T
3; T
3; T
ir
i
L
;
1
if
2
if
3
3
if
if

Publicité

Table des Matières
loading

Table des Matières