Code
No.
Name
C0323
Ramp function
generator input
(A)
(NSET1-RFG1-IN)
C0324
Ramp function
generator output
(A)
(NSET1-NOUT)
C0325
PID controller output
(PCTRL1-PID-OUT)
(A)
C0320
Process controller
output
(A)
(PCTRL1-NOUT)
C0350*
System bus node
v
address
C0351*
System bus baud
y
v
rate
C0352*
Configuration of
g
v
system bus devices
C0353*
System bus address
v
source
1 CAN1 (sync)
2 CAN2
3 CAN1 (time)
C0354*
Selective system bus
v
address
1 CAN-IN1 (sync)
2 CAN-OUT1 (sync)
3 CAN-IN2
4 CAN-OUT2
5 CAN-IN1 (time)
6 CAN-OUT1 (time)
C0355*
System bus identifier
v
1 CAN-IN1
2 CAN-OUT1
3 CAN-IN2
4 CAN-OUT2
5 CAN-IN1
6 CAN-OUT1
C0356*
System bus time
v
settings
1 Boot up
2 Cycle time
CAN-OUT2
3 Cycle time
CAN-OUT1
4 CAN delay
L
Possible settings
Lenze
Selection
1
1
0
0
1
2
3
4
5
0
0
b
d i
1
0
0
0
1
0
0
129
1
257
258
385
386
0
0
3000
0
0
20
{1}
500 kbit/s
250 kbit/s
125 kbit/s
50 kbit/s
1000 kbit/s (presently not supported)
20 kbit/s
Slave
Master
C0350 is source
C0354 is the source
{1}
{1}
{
{1 ms}
}
EDK82EV903 DE/EN/FR 1.0
Commissioning
Code table
IMPORTANT
Only display
Only display
Only display
Only display
63 Changes will become effective after the
command "reset node"
Changes will become effective after the
g
command "reset node"
d "
d "
Changes will become effective after the
g
command "reset node"
d "
d "
Address source for system bus process data
channels
Effective with sync control (C0360 = 1)
Effective with event and time control (C0360 =
0)
513 Individual addressing of system bus process
data objects
Effective with sync control (C0360 = 1)
y
Effective with event and time control (C0360 =
0)
0)
2047 Only display
Identifier of CAN1 with sync control (C0360 = 1)
y
Identifier of CAN1 with event or time control
(C0360
(C0360 = 0)
0)
65000 Required for CAN network without master
0 and C0360 = 0: event-controlled process data
transfer
> 0 and C0360 = 1: cyclic process data transfer
0 = event-controlled process data transfer
> 0 = cyclic process data transfer
Waiting time until cyclic sending after boot-up
(
)
(
(
)
63