Code
No.
Name
C0412
Free configuration of
v
analog input signals
1 Setpoint 1
(NSET1–N1)
2 Setpoint 2
(NSET1-N2)
3 Additional setpoint
(PCTRL1-NADD)
4 Process controller
setpoint 1
(PCTRL1-SET1)
5 Act. process
controller value
(PCTRL1-ACT)
6 Torque setpoint or
torque limit value
(MCTRL1-MSET)
7 Reserved
8 MCTRL1-VOLT-ADD
9 MCTRL1-PHI-ADD
C0413* Offset analog inputs
1 AIN1-OFFSET
2 AIN2-OFFSET
C0414* Analog input gain
1 AIN1-GAIN
2 AIN2-GAIN
L
Possible settings
Lenze
Selection
Connection between external analog signal sources
and internal analog signals
Analog signal source
1
0
not assigned (FIXED-FREE) or selection via keypad or
parameter channel of an AIF bus module
255
1
1
X3/8 or X3/1U, X3/1I (AIN1-OUT)
255
2
Frequency input (DFIN1-OUT)
(Observe C0410/24, C0425, C0426, C0427)
255
3
Motor potentiometer (MPOT1-OUT)
4
X3/2U, X3/2I (AIN2-OUT, application I/O only)
255
5 ... 9
Input signal = constantly 0 (FIXED0)
255
10
AIF input word 1 (AIF-IN.W1)
11
AIF input word 2 (AIF-IN.W2)
(Only evaluated if C0001 =3!)
255
20 ... 23
CAN-IN1.W1 ... W4/FIF-IN.W1 ... W4
Word 1 (20) ... word 4 (23)
255
30 ... 33
CAN-IN2.W1 ... W4
Word 1 (24) ... word 4 (27)
255
200
Word-by-word assignment of signals from the
function module INTERBUS or PROFIBUS to FIF (see
C0005)
228 (A)
PCTRL1-ACT
229 (A)
PCTRL1-SET
230 (A)
PCTRL1-OUT
231 (A)
NSET1-RFG1-IN
232 (A)
NSET1-NOUT
233 (A)
PCTRL1-PID-OUT
234 (A)
PCTRL1-NOUT
0.0
-200.0
0.0
-1500.0
100.0
100.0
EDK82EV903 DE/EN/FR 1.0
Commissioning
{0.1 %}
200.0 Settings for X3/8 and X3/1U, X3/1I
{0.1 %}
1500.0 Settings for X3/8 and X3/1U, X3/1I
Code table
IMPORTANT
A selection made under C0005, C0007 will
be copied to the corresponding subcode of
C0412. A change of C0412 sets C0005 =
255, C0007 = 255!
Either NSET1-N1 or NSET1-N2
Parameter
active
channel: C0046
Changeover with C0410/17
Ch
i h C0410/1
Parameter
channel: C0044
Is added to NSET1-N1,
Parameter
NSET1-N2, JOG values and
channel: C0049
j
the function
of the
keypad
Parameter
channel:
C0051, if
C0238 = 1, 2
Observe C0014!
Parameter
channel: C0047
Actual torque values not
required.
16384 ≡ 100 % torque
setpoint
Condition for selection via
terminal (C0412/6 = 1, 2
oder 4):
– The gain of the analog
input is set to: C0414/x,
C0426 = 32768/C0011
[%]
Only for special applications. Modifications only
when agreed on by Lenze!
g
y
The max. limit of the setpoint value range of
C0034 equals 100 %
C0413/1 and C0026 are identical
Setting for X3/2U, X3/2I
(application I/O only)
100.0 % = Gain 1
Inverse setpoint selection by negative gain
and negative offset
C0414/1 and C0027 are identical
Setting for X3/2U, X3/2I
(application I/O only)