VM Motori R754EU5 Instructions Pour L'emploi page 112

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3- Prepare a container of appropriate
capacity.
4- Loosen the screw (E).
GB
Do not loosen high-pressure pipe
unions of the supply circuit (CommoN
RAIL system).
5- Operate the pump (F) manually to
eliminate air from the circuit.
6-Check that a flow of clean fuel contai-
ning no air bubbles is coming out of the
bleeder screw (E).
ENGINE oIL LEVEL CoNTRoL
Follow the procedure below.
1- Start the engine and bring it to the ope-
rating temperature (70÷80 °C).
2- Turn off the engine and remove the
ignition key.
3- Place the engine on a perfectly level
surface.
4-Wait a few minutes so that all the oil will
flow into the sump.
5-Remove the dipstick (L) and check the
oil level.
6- Top up, if necessary, from plug (M). As
for the oil quantity, see "Technical data ".
The oil level should be included
between the minimum and maximum
marks. Do not mix oils of different
brands or with different features. (See
"Recommended lubricants")
English
R750EU5 - IE3 - TE4 - IE4 - ISE4
Be careful to ensure that the fuel in the
filter does not drain completely out.
If it does, remove it (see "Fuel filter
replacement."), fill it manually and then
repeat the bleeding operation.
7- Tighten the screw (E).
8- Wipe out the fuel residues before star-
ting the engine.
Oil Dipstick (L)
48
Filler Cap (M)
Ed.8 / 0-202

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R756eu5R754ie3R756ie3R754te4R754ie4R754ise4

Table des Matières