Replacing The Carbon Brushes; Replacing The Table Insert; Transport - ATIKA KGSZ 305 N Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Cleaning
Observe the following to maintain the functionality of
the saw.
 Do not wash down device with water.
 Remove splints and sawdust only with a brush or vacuum
cleaner.
 Clean and oil all moving parts regularly.
Never use any grease!
Use for instance sewing machine oil, liquid hydraulic
fluid or environmentally acceptable spray oil.
 Take care that the saw blade remains free of rust and resin.
 Remove resin residues from the surface of the rotary table.
Resin residues can be removed with a commercial
maintenance and care spray.
 The saw blade is a wearing part and will become dull after
prolonged or frequent use.
Replace the saw blade in that case.
 Thoroughly shake out the dust bag. Wash the dust bag in
case of heavy soiling but at least once a year with a mild
soap solution.
Maintenance
Changing the saw blade
Danger of cutting! Wear gloves when replacing the
saw blade.
If possible, carry saw blades in a container.
Use only suitable saw blades.
Danger of burning! The saw blade is still hot shortly
after cutting.
1. Secure the pulling mechanism.
2. Place the saw head to the top position.
3. 
Loosen the screw (A).
4. 
Schwenken Sie die Halteplatte (16A) für die
Pendelschutzhaube und die Pendelschutzhaube (16) nach
oben.
5. 
Push the saw blade locking device (38).
6. Slowly turn the saw blade by hand until the saw blade
locking device catches. Keep the saw blade locking device
pressed.
7. 
Unscrew the hexagonal screw (34) for the saw blade
(
left-handed thread) using the supplied tool (44).
8. 
/
Now, the front saw blade flange (35), the saw
blade (36) and the rear saw blade flange (37) can be
removed.
Clean the saw blade flanges.
9. Position the rear saw blade flange again.
10. Insert a new saw blade.
Pay attention to the correct running direction of the saw
blade: The arrow on the saw blade and the arrow on
the protective cover must point in the same direction!
11. Position the front saw blade flange again.
12. The further assembly is now done in reverse sequence.
Retighten the hexagon screw.
24
13. Check the pendulum cover for its correct functioning before
proceeding.

Replacing the carbon brushes

Replace the carbon brushes once they have been worn down to
approx. 4 mm.
1. 
Remove the carbon brush cover (4) on the side of the
motor cover by turning it counter clockwise using a suitable
screw driver.
2. 
Remove the carbon brushes (43); note the position of
the spring retention.
3. Insert the new carbon brushes observing the correct position
of the spring retention.
4. Replace the carbon brushes only in pairs.
5. Screw in the carbon brush cover (4) again.

Replacing the table insert

Immediately replace a worn or damaged table insert.
1.
Remove the screws (12) of the work piece stop (11) and
remove the latter.
2.
Loosen the screws of the table insert (9) and remove
them.
3. Insert a new table insert and screw it tightly in place.
4.
Align the tool stop to a stop angle (A, not supplied) and
retighten it.

Transport

Remove mains plug before each transport.
Before each transport:
 Position saw head vertically
 Turn rotary table to 0°
 Push saw head down and engage the transport locking
pin (5)
 Remove the support arms (18) and the vise assembly
(20)
 Secure the pulling device!
 Carry the saw on its transport handle (2).
Always carry the saw on the carrying handle (2) or on
the outer cast parts. Do not hold the saw on the
protective covers or handle (1) when lifting it.

Publicité