Télécharger Imprimer la page

Opex Mail Matrix Manuel De L'opérateur page 284

Publicité

Incompatible iBOTs
Detected
Feeder Section E-
Stop
Second Charging
Rail Extended
Sensor Blocked
Third Charging Rail
Extended Sensor
Blocked
Second Charging
Rail Retracted
Sensor Blocked
Third Charging Rail
Retracted Sensor
Blocked
Critical iBOT Power
Detected
Labeler Skew
Sensor Blocked
Labeler Response
Missing
Labeler Fault
Detected
Verifier Response
Missing
142
Results when the controller detects incompatible
iBOTs within the machine. Can happen if the
controller is upgraded and the iBOTs are not when an
iBOT upgrade is necessary.
Results when the feeder section E-Stop has been
pressed.
Results when the second charging rail extended
sensor is blocked on startup.
Results when the third charging rail extended sensor
is blocked on startup.
Results when the second charging rail retracted
sensor remains blocked on startup.
Results when the third charging rail retracted sensor
remains blocked on startup.
Results when the controller detects that an iBOT's
power level has reached critical.
Results when the labeler skew sensor remains
blocked on startup.
Results when there is no response from the labeler
following a command within the timeout period.
Results when a fault is detected by the labeler. The
various kinds of faults include: Unable to Home,
Unable to Extend, Label Missing, Trigger Detected
While Not in Home Position, Home Sensor Not
Blocked, Home and Extend Sensors Blocked, Extend
Sensor Blocked, Arm Movement Not Detected and
Label Presence Detected.
Results when there is no response from the verifier
following a command within the timeout period.