Note: The Pause feature is used to stop the input conveyor and auto-
feeder if used. After clicking the Pause button, it changes to Resume.
Click Resume to restart the input conveyor.
5. The conveyor will carry your mail past the camera and to an awaiting iBOT.
The camera will capture the image, the MLOCR software will interpret the
text, and the DRS will attempt to assign a bin.
• If the software cannot determine the recipient, the image will be sent to
an available Keying Station, either at the operator station or at an
installed, active KFI module.
• If the piece is not identified in a specified period of time, the piece will be
sent to the reject bin.
6. The iBOT delivers the mail piece to the appropriate bin.
- When an iBOT is at the top of the loading column waiting to be
keyed and two iBOTs accumulate below with destinations, the iBOT
will exit the loading column then re-enter from below (recirculate).
- When two iBOTs are at the top of the loading column waiting to be
keyed and three iBOTs accumulate below with destinations, the
iBOTs will recirculate.